Location Selection

Location of a water conditioning system is important.  
The following conditions are required:

• 

Level platform or floor.

Note: 

The Pro Elite System can be provided with 

optional leveling feet that may be used on the two 

tanks. Order part number 4000409.

•  Room to access equipment for maintenance 

and adding regenerant (salt) to tank.

•  Ambient temperatures over 34°F 

(1°C and below 120°F (49°C).

• 

Water pressure below 125 psi (8.62 

bar) and above 20 psi (1.38 bar).

•  In Canada the water pressure must 

be below 100 psi (6.89 bar).

•  Constant electrical supply to operate the control.
•  Total minimum pipe run to water heater 

of ten feet (three meters) to prevent 
backup of hot water into system.

•  Local drain for discharge as close as possible.
•  Water line connections with 

shutoff or bypass valves.

•  Must meet any local and state 

codes for site of installation.

•  Valve is designed for minor plumbing 

misalignments. Do not support weight 
of system on the plumbing.

•  Be sure all soldered pipes are fully cooled before 

attaching plastic valve to the plumbing.

 

WARNING: 

Dry location use only, unless 

used with a Listed Class 2 Power Supply 
suitable for outdoor use.

Outdoor Locations

It is recommended that the Pro Elite conditioner be 
installed in a protected environment.
When installing the water conditioning system outdoors, 
several items must be considered:

•  Moisture – The valve and control are rated 

for NEMA 3 locations. Falling water should 
not affect performance.  The system is not 
designed to withstand extreme humidity 
or water spray from below. Examples 
are:  constant heavy mist, near corrosive 
environment, or upwards spray from sprinkler. 

•  Direct Sunlight – The materials used will fade 

or discolor over time in direct sunlight. The 
integrity of the materials will not degrade to 
cause system failures.

•  Temperature – Extreme hot or cold temperatures 

will cause damage to the valve or control. Freezing 
temperatures will freeze the water in the valve. This 
will cause physical damage to the internal parts as 
well as the plumbing and conditioning resin. High 
temperatures will affect the control. The display 
may become unreadable but the control should 
continue to function. When the temperature returns 
to normal operating limits, the display will re-
appear. A protective cover should assist with high 
temperature applications.

•  Insects – The control and valve have been designed 

to keep all but the smallest insects out of the 
critical areas. Any holes in the top plate can be 
covered with duct tape. The top cover should be 
installed securely in place.

6 • 

PENTAIR 

Pro Elite Professional Series Pro Elite Demand Instruction Manual

Содержание Pro Elite 268-762-100-1044 Demand

Страница 1: ...PRO ELITE PROFESSIONAL SERIES PRO ELITE DEMAND WATER TREATMENT SYSTEM OPERATION MANUAL...

Страница 2: ...ors 17 Button Functions 17 Programming Overview 18 Demand Control Operation 18 Level I Programming 18 Level l Programming Demand Conditioner 19 Level II Programming P Values 21 Level I Programming P V...

Страница 3: ...mplies with specific performance specifications intended to minimize the amount of regenerant brine and water used in its operation Efficiency rated water softeners shall have a rated salt efficiency...

Страница 4: ...tions that do not use an O ring seal Do not use pipe dope type sealants on the valve body Do not use pliers or pipe wrenches Do not use petroleum based lubricants such as petroleum jelly oils or hydro...

Страница 5: ...orage 240 lbs 109 kg 240 lbs 109 kg 240 lbs 109 kg Drain Water Rate 2 7 gpm 10 2 L m 3 9 gpm 14 7 L m 3 9 gpm 14 7 L m Service Connection Size 1 NPT 1 NPT 1 NPT Drain Connection Size 3 4 NPT 3 4 NPT 3...

Страница 6: ...itioner be installed in a protected environment When installing the water conditioning system outdoors several items must be considered Moisture The valve and control are rated for NEMA 3 locations Fa...

Страница 7: ...tch Mechanism 4 Base 11 Tank Collar 5 268 Logix PE Valve w 762 Control 12 Riser Tube 6 Resin Tank 13 Upper Basket 7 Shield Brine Tank 1 2 3 4 5 6 7 1 Cover 5 Brine Tube Assembly 2 Collar Tank 6 Foot L...

Страница 8: ...Dimensions 36 9 938 1 60 7 1541 6 19 8 503 8 16 8 427 1 17 6 447 20 5 521 1 35 1 890 4 28 2 715 9 32 2 817 5 53 4 1356 6 55 1398 1 5 0 127 2 5 63 5 8 PENTAIR Pro Elite Professional Series Pro Elite De...

Страница 9: ...Before Installation Cold water lines shown Soft Water Hard Water Outside Faucet Outside Faucet Bath Tub Lavatory Toilet Kitchen Laundry Tubs Pump or Meter Hot Water Outlet Water Heater Brine Tank Ove...

Страница 10: ...and the salt tank up and in position Level as needed The tank has two ports that will be connected One to a drain and one to the valve 3 Place the brine tube in position inside the pocket at the botto...

Страница 11: ...Model 1265 Bypass Included Water Conditioner Water Conditioner Water Conditioner Water Conditioner Normal Operation In Bypass Figure 6 Typical Three Valve Bypass Configuration Not provided by manufac...

Страница 12: ...r wire the hose in place at the drain point Also provide an air gap of at least 1 1 2 inch between the end of the hose and the drain point 5 When the drain empties into an overhead sewer line a sink t...

Страница 13: ...hose in place Drain Air Gap Figure 10 Electrical Connection Note There are no user serviceable parts in the AC adapter motor or the control board The Demand control operates on a 12 volt alternating c...

Страница 14: ...heck closes Slow Rinse Downflow Cycle C3 Water flow moves the regenerant through the resin at a specific rate and rinses to the drain The resin is regenerated Repressurization Cycle C4 Pressure is bal...

Страница 15: ...tely 90 degrees out of phase Note If electrical power is not available the camshaft can be rotated counterclockwise by hand if the motor is removed Cycle Indicators 0 Treated Water or brine make up if...

Страница 16: ...Dosage Polystyrene resin 1 2 fluid ounce 35 5 mL per cubic foot Non resinous exchangers 0 8 fluid ounce 23 7 mL per cubic foot 2 Regenerant tank conditioners A Backwash the conditioner and add the re...

Страница 17: ...cycle Appears as a solid icon during a cancelled regeneration and the control is cycling directly back to the home position 13 Indicates the selected program setting has been locked out Lock settings...

Страница 18: ...the information in memory for 8 to 24 hours depending on the installation If the super capacitor is exhausted the Demand control will display four dashes immediately upon power up The Time of Day and...

Страница 19: ...en regeneration 7 Salt Dosage Set to desired desired dosage lbs per cubic feet of resin Screen Buttons to Description Range Press Days 1 to 30 Lbs ft3 3 to 18 or press then or press press then or pres...

Страница 20: ...in 2 00 AM Hr Min Range dependent on value selected for P10 Clock mode P4 Calendar Override 0 99 1 3 Days 0 No calendar override 0 5 Regeneration twice a day at time of regeneration and 12 hours later...

Страница 21: ...te switch must be active to start regeneration on 742 time clock units P13 Chlorine Generator Options 0 2 1 0 0 No Chlorine Generator 1 Salt Check Only 2 Generate Chlorine P14 Refill Rate 1 700 1 1 gp...

Страница 22: ...lue Note The control must be in the treated water position to change settings C Description Range Minimum Increments Default Setting Notes C1 Backwash 0 200 1 Min 10 Flow rate dictated by size of drai...

Страница 23: ...for Thursday in gallons or m3 0 131 070 gallons or 0 1 310 70 m3 762 only H12 Average usage for Friday in gallons or m3 0 131 070 gallons or 0 1 310 70 m3 762 only H13 Average usage for Saturday in ga...

Страница 24: ...lass is no longer displayed and the motor will turn off Pressing the SET button will display the time remaining for the current cycle 4 Fill the media tank with water A While the Demand control is in...

Страница 25: ...ly 9 Finally turn on a faucet plumbed after the water conditioner Run the faucet until the water runs clear 10 Add the appropriate amount of regenerant to the regenerant tank The Water Conditioning Sy...

Страница 26: ...eneration icon will be displayed The control will immediately begin a regeneration Delayed Second Regeneration Pressing and releasing the REGEN button while the control is in regeneration will program...

Страница 27: ...Pro Elite Valve Exploded View and Parts List BYPASS BYPASS 20 21 22 23 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 18 19 11 12 PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual 27...

Страница 28: ...585 Skirt Pro Elite Lt Gray 1 19 1232370 O Ring Riser Tube 1 8 1000813 Transformer 230 240 VAC 50 60 Hz 12 VAC British Plug 1 20 1040930 1265 Bypass Valve 1 9 3019221 Motor Optical Cable 1 21 Drain Li...

Страница 29: ...4 2 3 4 5 6 7 9 10 12 13 14 15 16 17 11 Conditioner Tank and Regenerant Tank Assembly Exploded View and Parts List 1 A A A 25 8 19 5 25 29 PENTAIR Pro Elite Professional Series Pro Elite Demand Instru...

Страница 30: ...e Torsion 2 9 4005393 Label Domed Button 1 4 Pentair Logo 1 22 4000359 Spring Torsion 2 10 4000347 Cover Brine Tank Pro Elite 1 23 4000358 Latch Cover Pro Elite 2 11 4000348 Collar Brine Tank Pro Elit...

Страница 31: ...4 1 6 60068 8 06 Brine Float w One Grommet As Purchased 1 7 60002 27 Air Check Assembly 1 8 BR10332 Tubing Insert Brass 2 CH20774 Overflow Fitting Assembly 1 CH15031 1 Overflow Elbow 1 CH15031 2 Overf...

Страница 32: ...isplay Check that motor is connected Verify that motor wire harness is connected to motor and control module Verify that optical sensor is connected and in place Verify that motor gear has engaged cam...

Страница 33: ...c Clean injector and screen d Replace injector and cap Contact dealer e Remove foreign matter from disc and check disc for closing by pushing in on stem Replace if needed Contact dealer f Put control...

Страница 34: ...34 PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual...

Страница 35: ...PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual 35...

Страница 36: ...4 tech support pentair com 2019 Pentair Residential Filtration LLC All rights reserved For a detailed list of where Pentair trademarks are registered please visit pentair com en registrations html Pen...

Отзывы: