Performance Data Sheet

Pro Elite Demand Water Softener System Performance Data Sheet

Model

Pro Elite  

268-762-100-1044  

Demand

Pro Elite  

268-762-150-1248  

Demand

Pro Elite  

268-762-200-1248  

Demand

Rated Service Flow (gpm)

12.0

13.0

14.4

Pressure Drop at Rated 

Service Flow Rate (psi)

11

12

15

Rated Capacity  

(grains @ lb of salt)

15,122 @ 3.3  lbs

 

21,716 @ 9.0  lbs

 

27,641 @ 15.0 lbs

25,746 @ 4.95  lbs

 

36,972 @ 13.5  lbs

 

47,059 @ 22.5  lbs

36,102 @ 6.6  lbs

 

51,844 @ 18.0  lbs

 

65,988 @ 30.0 lbs

Rated Efficiency

 

(grains/lb Salt @ lb of salt) 

4,582 grains/lb @ 3.3 lbs

5,201 grains/lb @ 4.95 lbs.

5,470 grains/lb @ 6.6 lbs

Maximum FLow Rate  

During Regeneration (gpm)

5.5

5.5

5.5

10% Cross Linked Ion 
Exchange Resin (cu ft)

1.0

1.5

2.0

Tank Size

10" x 44"

12" x 48"

12" x 48"

Backwash - GPM

2.7

3.9

3.9

Rapid Rinse/Purge - GPM

5.5

5.5

5.5

Operating Pressure: 20-125 psi or 1.4-8.8 kg/cm

2

, Operating Temperature: 34-100°F or 1.1-43.3°C

 

Acceptable Salt Type: Sodium Chloride - Pellet salt 

All Systems above tested at 35 psi ±5 psi, pH of 7.5 ±0.5, Capacity Testing Flow Rate = 50% of the rated service flow rate for the 

various size systems.

These water softener systems have been tested by WQA and conform to NSF/ANSI 44 for specific 
performance claims as verified and substantiated by test data.  The rated salt efficiencies above were 

also determined in accordance with NSF/ANSI 44 and are only valid at the salt dosage referenced above.  

An efficiency rated water softener is a demand initiated regeneration (DIR) softener which also complies 
with specific performance specifications intended to minimize the amount of regenerant brine and water 
used in its operation.  Efficiency rated water softeners shall have a rated salt efficiency of not less that 
3350 grains of total hardness exchanged per pound of salt (based on NaCl equivalency) (477 grams of 
total hardness exchanged per kilogram of salt), and shall not deliver more salt than its listed rating.  The 
rated efficiency of the water softener, the salt dosage at that efficiency, the capacity at that salt dosage 
and that of the efficiency is only valid at the stated salt dosage.  Efficiency is measured by a laboratory 
test described in NSF/ANSI 44.  The test represents the maximum possible efficiency the system can 
achieve.  Operational efficiency is the actual efficiency achieved after the system has been installed.  It 
is typically less than the efficiency due to individual application factors including water hardness, water 

usage, and other contaminants that reduce the water softener’s capacity.  These systems are not intended 
to be used for treating water that is microbiologically unsafe or of unknown quality without adequate 
disinfection before or after the system.  Refer to the system Installation and Service Manuals for set-up 
and programming instructions.
Contact your local dealer for parts and service.  See your owner’s manual for warranty information

Tested and Certified by 

WQA against NSF/ANSI 

Std. 44 & 372 for “lead free” 

compliance & CSA B483.1.

PENTAIR Residential Filtration, LLC 

13845 Bishops Drive Suite 200

 

Brookfield, WI 53005

 

PHONE: (262) 238-4400

2/01/19

PENTAIR 

Pro Elite Professional Series Pro Elite Demand Instruction Manual • 3

Содержание Pro Elite 268-762-100-1044 Demand

Страница 1: ...PRO ELITE PROFESSIONAL SERIES PRO ELITE DEMAND WATER TREATMENT SYSTEM OPERATION MANUAL...

Страница 2: ...ors 17 Button Functions 17 Programming Overview 18 Demand Control Operation 18 Level I Programming 18 Level l Programming Demand Conditioner 19 Level II Programming P Values 21 Level I Programming P V...

Страница 3: ...mplies with specific performance specifications intended to minimize the amount of regenerant brine and water used in its operation Efficiency rated water softeners shall have a rated salt efficiency...

Страница 4: ...tions that do not use an O ring seal Do not use pipe dope type sealants on the valve body Do not use pliers or pipe wrenches Do not use petroleum based lubricants such as petroleum jelly oils or hydro...

Страница 5: ...orage 240 lbs 109 kg 240 lbs 109 kg 240 lbs 109 kg Drain Water Rate 2 7 gpm 10 2 L m 3 9 gpm 14 7 L m 3 9 gpm 14 7 L m Service Connection Size 1 NPT 1 NPT 1 NPT Drain Connection Size 3 4 NPT 3 4 NPT 3...

Страница 6: ...itioner be installed in a protected environment When installing the water conditioning system outdoors several items must be considered Moisture The valve and control are rated for NEMA 3 locations Fa...

Страница 7: ...tch Mechanism 4 Base 11 Tank Collar 5 268 Logix PE Valve w 762 Control 12 Riser Tube 6 Resin Tank 13 Upper Basket 7 Shield Brine Tank 1 2 3 4 5 6 7 1 Cover 5 Brine Tube Assembly 2 Collar Tank 6 Foot L...

Страница 8: ...Dimensions 36 9 938 1 60 7 1541 6 19 8 503 8 16 8 427 1 17 6 447 20 5 521 1 35 1 890 4 28 2 715 9 32 2 817 5 53 4 1356 6 55 1398 1 5 0 127 2 5 63 5 8 PENTAIR Pro Elite Professional Series Pro Elite De...

Страница 9: ...Before Installation Cold water lines shown Soft Water Hard Water Outside Faucet Outside Faucet Bath Tub Lavatory Toilet Kitchen Laundry Tubs Pump or Meter Hot Water Outlet Water Heater Brine Tank Ove...

Страница 10: ...and the salt tank up and in position Level as needed The tank has two ports that will be connected One to a drain and one to the valve 3 Place the brine tube in position inside the pocket at the botto...

Страница 11: ...Model 1265 Bypass Included Water Conditioner Water Conditioner Water Conditioner Water Conditioner Normal Operation In Bypass Figure 6 Typical Three Valve Bypass Configuration Not provided by manufac...

Страница 12: ...r wire the hose in place at the drain point Also provide an air gap of at least 1 1 2 inch between the end of the hose and the drain point 5 When the drain empties into an overhead sewer line a sink t...

Страница 13: ...hose in place Drain Air Gap Figure 10 Electrical Connection Note There are no user serviceable parts in the AC adapter motor or the control board The Demand control operates on a 12 volt alternating c...

Страница 14: ...heck closes Slow Rinse Downflow Cycle C3 Water flow moves the regenerant through the resin at a specific rate and rinses to the drain The resin is regenerated Repressurization Cycle C4 Pressure is bal...

Страница 15: ...tely 90 degrees out of phase Note If electrical power is not available the camshaft can be rotated counterclockwise by hand if the motor is removed Cycle Indicators 0 Treated Water or brine make up if...

Страница 16: ...Dosage Polystyrene resin 1 2 fluid ounce 35 5 mL per cubic foot Non resinous exchangers 0 8 fluid ounce 23 7 mL per cubic foot 2 Regenerant tank conditioners A Backwash the conditioner and add the re...

Страница 17: ...cycle Appears as a solid icon during a cancelled regeneration and the control is cycling directly back to the home position 13 Indicates the selected program setting has been locked out Lock settings...

Страница 18: ...the information in memory for 8 to 24 hours depending on the installation If the super capacitor is exhausted the Demand control will display four dashes immediately upon power up The Time of Day and...

Страница 19: ...en regeneration 7 Salt Dosage Set to desired desired dosage lbs per cubic feet of resin Screen Buttons to Description Range Press Days 1 to 30 Lbs ft3 3 to 18 or press then or press press then or pres...

Страница 20: ...in 2 00 AM Hr Min Range dependent on value selected for P10 Clock mode P4 Calendar Override 0 99 1 3 Days 0 No calendar override 0 5 Regeneration twice a day at time of regeneration and 12 hours later...

Страница 21: ...te switch must be active to start regeneration on 742 time clock units P13 Chlorine Generator Options 0 2 1 0 0 No Chlorine Generator 1 Salt Check Only 2 Generate Chlorine P14 Refill Rate 1 700 1 1 gp...

Страница 22: ...lue Note The control must be in the treated water position to change settings C Description Range Minimum Increments Default Setting Notes C1 Backwash 0 200 1 Min 10 Flow rate dictated by size of drai...

Страница 23: ...for Thursday in gallons or m3 0 131 070 gallons or 0 1 310 70 m3 762 only H12 Average usage for Friday in gallons or m3 0 131 070 gallons or 0 1 310 70 m3 762 only H13 Average usage for Saturday in ga...

Страница 24: ...lass is no longer displayed and the motor will turn off Pressing the SET button will display the time remaining for the current cycle 4 Fill the media tank with water A While the Demand control is in...

Страница 25: ...ly 9 Finally turn on a faucet plumbed after the water conditioner Run the faucet until the water runs clear 10 Add the appropriate amount of regenerant to the regenerant tank The Water Conditioning Sy...

Страница 26: ...eneration icon will be displayed The control will immediately begin a regeneration Delayed Second Regeneration Pressing and releasing the REGEN button while the control is in regeneration will program...

Страница 27: ...Pro Elite Valve Exploded View and Parts List BYPASS BYPASS 20 21 22 23 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 18 19 11 12 PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual 27...

Страница 28: ...585 Skirt Pro Elite Lt Gray 1 19 1232370 O Ring Riser Tube 1 8 1000813 Transformer 230 240 VAC 50 60 Hz 12 VAC British Plug 1 20 1040930 1265 Bypass Valve 1 9 3019221 Motor Optical Cable 1 21 Drain Li...

Страница 29: ...4 2 3 4 5 6 7 9 10 12 13 14 15 16 17 11 Conditioner Tank and Regenerant Tank Assembly Exploded View and Parts List 1 A A A 25 8 19 5 25 29 PENTAIR Pro Elite Professional Series Pro Elite Demand Instru...

Страница 30: ...e Torsion 2 9 4005393 Label Domed Button 1 4 Pentair Logo 1 22 4000359 Spring Torsion 2 10 4000347 Cover Brine Tank Pro Elite 1 23 4000358 Latch Cover Pro Elite 2 11 4000348 Collar Brine Tank Pro Elit...

Страница 31: ...4 1 6 60068 8 06 Brine Float w One Grommet As Purchased 1 7 60002 27 Air Check Assembly 1 8 BR10332 Tubing Insert Brass 2 CH20774 Overflow Fitting Assembly 1 CH15031 1 Overflow Elbow 1 CH15031 2 Overf...

Страница 32: ...isplay Check that motor is connected Verify that motor wire harness is connected to motor and control module Verify that optical sensor is connected and in place Verify that motor gear has engaged cam...

Страница 33: ...c Clean injector and screen d Replace injector and cap Contact dealer e Remove foreign matter from disc and check disc for closing by pushing in on stem Replace if needed Contact dealer f Put control...

Страница 34: ...34 PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual...

Страница 35: ...PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual 35...

Страница 36: ...4 tech support pentair com 2019 Pentair Residential Filtration LLC All rights reserved For a detailed list of where Pentair trademarks are registered please visit pentair com en registrations html Pen...

Отзывы: