Level IV Viewing History - H Values
Historical information can be viewed by pressing the
SET and DOWN buttons simultaneously with the Demand
control in the home position. Release both buttons when
the control displays an “H” value. Press the UP or DOWN
buttons to navigate to each setting.
H#
Description
Range
Notes
H0
Initial Setting Value
Cubic Feet or Liters
Resin Volume
H1
Days since last regeneration
0 - 255
H2
Current Flow Rate
Depends on Turbine Used
762 only
H3
Water used today in gallons/m
3
since Time of
Regeneration
0 - 131,070 gallons or 0 - 1,310.70 m
3
762 only
H4
Water used since last regeneration in gallons/m
3
0 - 131,070 gallons or 0 - 1,310.70 m
3
762 only
H5
Total water used since reset in 100s
0 - 999,900 gallons or 0 - 0000 m
3
762 only
H6
Total water used since reset in 1,000,000s
4,294 x 10
6
gallons or 4,264 x 10
4
m
3
762 only
H7
Average usage for Sunday in gallons or m
3
0 - 131,070 gallons or 0 - 1,310.70 m
3
762 only
H8
Average usage for Monday in gallons or m
3
0 - 131,070 gallons or 0 - 1,310.70 m
3
762 only
H9
Average usage for Tuesday in gallons or m
3
0 - 131,070 gallons or 0 - 1,310.70 m
3
762 only
H10
Average usage for Wednesday in gallons or m
3
0 - 131,070 gallons or 0 - 1,310.70 m
3
762 only
H11
Average usage for Thursday in gallons or m
3
0 - 131,070 gallons or 0 - 1,310.70 m
3
762 only
H12
Average usage for Friday in gallons or m
3
0 - 131,070 gallons or 0 - 1,310.70 m
3
762 only
H13
Average usage for Saturday in gallons or m
3
0 - 131,070 gallons or 0 - 1,310.70 m
3
762 only
H14
Average service cycle
0 - 255 days
762 only
H15
Peak Flow Rate
0 - 200 gpm or 1000 lpm
762 only
H16
Day and Time of Peak Flow Rate
Time and day that peak flow rate occurred 762 only
H17
Months since last serviced
0 - 2,184 Months
H r
Number of regenerations since last serviced
0 - 65,536
Program Reset
The Demand control can be reset to original factory
parameters when viewing the H0 parameter. Press
and hold the SET button for three seconds while H0 is
displayed. Release the button. All settings except for
Time of Day and Day of Week will be reset. The Demand
control will now display three dashes indicating that the
resin volume must be set.
System Capacities
The Demand control software contains the following
preloaded system capacities for each salt setting (please
see the Performance Data Sheet on page 3 for certified
claims):
Salt: Lbs/Ft
3
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Cap KG: 10x44 1.00
14
18
21
23
25
27
28
30
31
32
33
34
35
36
36
37
Cap KG: 12x48 1.50
21
27
31
35
38
40
43
45
46
48
50
51
52
54
55
56
Cap KG: 12x48 2.00
28
36
42
46
50
54
56
60
62
64
66
68
70
72
72
74
PENTAIR
Pro Elite Professional Series Pro Elite Demand Instruction Manual • 23