Pentair Pro Elite
268-762-100-1044 Demand Скачать руководство пользователя страница 18

Programming Overview

The Demand control includes multiple program levels 
that allow the Water Treatment Professional to customize 
the system for many water conditions. Additionally, 
historical data can be viewed allowing quick and easy 
troubleshooting.  In most cases, Level I programming 
is all that is required to set up the water conditioning 
system for proper operation. A brief description of each 
program level is listed below.
• 

Level l:  Used to program control for normal 
applications..

• 

Level ll: (P-Values)   Allows the installer to customize 
programming for non-standard applications.

• 

Level lll: (C-Values)   Allows the installer to adjust the 
length of select cycles for non-standard applications.

• 

Level IV: History (H-Values)   Allows access to 
historical information for troubleshooting the system.

Note: 

If a button is not pushed for thirty seconds, the 

control returns to normal operation mode.

Demand Control Operation

Power Loss Memory Retention

The Demand control features battery-free Time of Day 
and Day of Week retention during loss of power. A super 
capacitor is designed to hold the information in memory 
for 8 to 24 hours depending on the installation. If the 
super capacitor is exhausted, the Demand control will 
display four dashes  (- - :- -) immediately upon power up.  
The Time of Day and Day of Week must be reset. 
All other programmed parameters are stored in the static 
memory and are retained during power outages. 

Level I Programming

The Demand control can be quickly programmed by 
following the sequential procedure on the following 
page. Level I program parameters are those that can be 
accessed by pressing the UP or DOWN buttons. 

• 

Valve Type: Select 268 for traditional refilling the 

salt tank last.

•  Resin Volume Setting: Set to match the volume 

(cubic feet) of resin in the mineral tank.

•  Time of Day: Includes PM indicator. Can be 

set to display as a 24-hour clock. See Level ll 
Programming.

•  Day of Week: Set to actual day of the week. 
•  Time of Regeneration: Fully adjustable. Default is 

2:00 AM.

• 

Days Override: Range 0.5 to 99 days.  Leave at 0 to 

disable.

•  Salt Dosage: Set at pounds of salt per cubic foot of 

resin in the conditioner tank. 

Note: 

When the control is set up for a twelve-hour clock 

a PM indicator will illuminate when the displayed time is 
in the PM hours. There is no AM indicator.

18 • 

PENTAIR 

Pro Elite Professional Series Pro Elite Demand Instruction Manual

Содержание Pro Elite 268-762-100-1044 Demand

Страница 1: ...PRO ELITE PROFESSIONAL SERIES PRO ELITE DEMAND WATER TREATMENT SYSTEM OPERATION MANUAL...

Страница 2: ...ors 17 Button Functions 17 Programming Overview 18 Demand Control Operation 18 Level I Programming 18 Level l Programming Demand Conditioner 19 Level II Programming P Values 21 Level I Programming P V...

Страница 3: ...mplies with specific performance specifications intended to minimize the amount of regenerant brine and water used in its operation Efficiency rated water softeners shall have a rated salt efficiency...

Страница 4: ...tions that do not use an O ring seal Do not use pipe dope type sealants on the valve body Do not use pliers or pipe wrenches Do not use petroleum based lubricants such as petroleum jelly oils or hydro...

Страница 5: ...orage 240 lbs 109 kg 240 lbs 109 kg 240 lbs 109 kg Drain Water Rate 2 7 gpm 10 2 L m 3 9 gpm 14 7 L m 3 9 gpm 14 7 L m Service Connection Size 1 NPT 1 NPT 1 NPT Drain Connection Size 3 4 NPT 3 4 NPT 3...

Страница 6: ...itioner be installed in a protected environment When installing the water conditioning system outdoors several items must be considered Moisture The valve and control are rated for NEMA 3 locations Fa...

Страница 7: ...tch Mechanism 4 Base 11 Tank Collar 5 268 Logix PE Valve w 762 Control 12 Riser Tube 6 Resin Tank 13 Upper Basket 7 Shield Brine Tank 1 2 3 4 5 6 7 1 Cover 5 Brine Tube Assembly 2 Collar Tank 6 Foot L...

Страница 8: ...Dimensions 36 9 938 1 60 7 1541 6 19 8 503 8 16 8 427 1 17 6 447 20 5 521 1 35 1 890 4 28 2 715 9 32 2 817 5 53 4 1356 6 55 1398 1 5 0 127 2 5 63 5 8 PENTAIR Pro Elite Professional Series Pro Elite De...

Страница 9: ...Before Installation Cold water lines shown Soft Water Hard Water Outside Faucet Outside Faucet Bath Tub Lavatory Toilet Kitchen Laundry Tubs Pump or Meter Hot Water Outlet Water Heater Brine Tank Ove...

Страница 10: ...and the salt tank up and in position Level as needed The tank has two ports that will be connected One to a drain and one to the valve 3 Place the brine tube in position inside the pocket at the botto...

Страница 11: ...Model 1265 Bypass Included Water Conditioner Water Conditioner Water Conditioner Water Conditioner Normal Operation In Bypass Figure 6 Typical Three Valve Bypass Configuration Not provided by manufac...

Страница 12: ...r wire the hose in place at the drain point Also provide an air gap of at least 1 1 2 inch between the end of the hose and the drain point 5 When the drain empties into an overhead sewer line a sink t...

Страница 13: ...hose in place Drain Air Gap Figure 10 Electrical Connection Note There are no user serviceable parts in the AC adapter motor or the control board The Demand control operates on a 12 volt alternating c...

Страница 14: ...heck closes Slow Rinse Downflow Cycle C3 Water flow moves the regenerant through the resin at a specific rate and rinses to the drain The resin is regenerated Repressurization Cycle C4 Pressure is bal...

Страница 15: ...tely 90 degrees out of phase Note If electrical power is not available the camshaft can be rotated counterclockwise by hand if the motor is removed Cycle Indicators 0 Treated Water or brine make up if...

Страница 16: ...Dosage Polystyrene resin 1 2 fluid ounce 35 5 mL per cubic foot Non resinous exchangers 0 8 fluid ounce 23 7 mL per cubic foot 2 Regenerant tank conditioners A Backwash the conditioner and add the re...

Страница 17: ...cycle Appears as a solid icon during a cancelled regeneration and the control is cycling directly back to the home position 13 Indicates the selected program setting has been locked out Lock settings...

Страница 18: ...the information in memory for 8 to 24 hours depending on the installation If the super capacitor is exhausted the Demand control will display four dashes immediately upon power up The Time of Day and...

Страница 19: ...en regeneration 7 Salt Dosage Set to desired desired dosage lbs per cubic feet of resin Screen Buttons to Description Range Press Days 1 to 30 Lbs ft3 3 to 18 or press then or press press then or pres...

Страница 20: ...in 2 00 AM Hr Min Range dependent on value selected for P10 Clock mode P4 Calendar Override 0 99 1 3 Days 0 No calendar override 0 5 Regeneration twice a day at time of regeneration and 12 hours later...

Страница 21: ...te switch must be active to start regeneration on 742 time clock units P13 Chlorine Generator Options 0 2 1 0 0 No Chlorine Generator 1 Salt Check Only 2 Generate Chlorine P14 Refill Rate 1 700 1 1 gp...

Страница 22: ...lue Note The control must be in the treated water position to change settings C Description Range Minimum Increments Default Setting Notes C1 Backwash 0 200 1 Min 10 Flow rate dictated by size of drai...

Страница 23: ...for Thursday in gallons or m3 0 131 070 gallons or 0 1 310 70 m3 762 only H12 Average usage for Friday in gallons or m3 0 131 070 gallons or 0 1 310 70 m3 762 only H13 Average usage for Saturday in ga...

Страница 24: ...lass is no longer displayed and the motor will turn off Pressing the SET button will display the time remaining for the current cycle 4 Fill the media tank with water A While the Demand control is in...

Страница 25: ...ly 9 Finally turn on a faucet plumbed after the water conditioner Run the faucet until the water runs clear 10 Add the appropriate amount of regenerant to the regenerant tank The Water Conditioning Sy...

Страница 26: ...eneration icon will be displayed The control will immediately begin a regeneration Delayed Second Regeneration Pressing and releasing the REGEN button while the control is in regeneration will program...

Страница 27: ...Pro Elite Valve Exploded View and Parts List BYPASS BYPASS 20 21 22 23 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 18 19 11 12 PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual 27...

Страница 28: ...585 Skirt Pro Elite Lt Gray 1 19 1232370 O Ring Riser Tube 1 8 1000813 Transformer 230 240 VAC 50 60 Hz 12 VAC British Plug 1 20 1040930 1265 Bypass Valve 1 9 3019221 Motor Optical Cable 1 21 Drain Li...

Страница 29: ...4 2 3 4 5 6 7 9 10 12 13 14 15 16 17 11 Conditioner Tank and Regenerant Tank Assembly Exploded View and Parts List 1 A A A 25 8 19 5 25 29 PENTAIR Pro Elite Professional Series Pro Elite Demand Instru...

Страница 30: ...e Torsion 2 9 4005393 Label Domed Button 1 4 Pentair Logo 1 22 4000359 Spring Torsion 2 10 4000347 Cover Brine Tank Pro Elite 1 23 4000358 Latch Cover Pro Elite 2 11 4000348 Collar Brine Tank Pro Elit...

Страница 31: ...4 1 6 60068 8 06 Brine Float w One Grommet As Purchased 1 7 60002 27 Air Check Assembly 1 8 BR10332 Tubing Insert Brass 2 CH20774 Overflow Fitting Assembly 1 CH15031 1 Overflow Elbow 1 CH15031 2 Overf...

Страница 32: ...isplay Check that motor is connected Verify that motor wire harness is connected to motor and control module Verify that optical sensor is connected and in place Verify that motor gear has engaged cam...

Страница 33: ...c Clean injector and screen d Replace injector and cap Contact dealer e Remove foreign matter from disc and check disc for closing by pushing in on stem Replace if needed Contact dealer f Put control...

Страница 34: ...34 PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual...

Страница 35: ...PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual 35...

Страница 36: ...4 tech support pentair com 2019 Pentair Residential Filtration LLC All rights reserved For a detailed list of where Pentair trademarks are registered please visit pentair com en registrations html Pen...

Отзывы: