![background image](http://html1.mh-extra.com/html/pentair/colorvision/colorvision_installation-and-user-manual_1524886015.webp)
COLORVISION Light Installation and User’s Guide
COLORVISION Light Installation and User’s Guide
11
1.
Turn off main electrical switch or circuit breaker.
2.
Feed cord through Niche and then through conduit to Junction Box or 12 Volt
AC Transformer.
3.
At the 12 VAC transformer or junction box, cut off any extra cord. Leave at
least six (6) inches (15.2 cm) of cord in the Junction Box or transformer to
facilitate the light installation, niche inspection. Cut off any extra cord.
4.
Strip back three (3) inches of the outer cord jacket to expose the two
insulated wires (be careful not to damage the insulation on the two (2) inner
wires). Strip back the two conductors. Be careful not to damage the copper
conductor.
5. Connect both (2) wires to the corresponding circuit wires in the Junction Box
or 12 Volt AC Transformer (black wire to power, white wire to common) and
secure the Junction Box cover in place.
D A N G E R !
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
Always disconnect power to the pool light at the circuit breaker
before servicing the light. Failure to do so could result in death
or serious injury to installer, serviceman, pool users, or others
due to electrical shock.
NOTE: This is a 12 Volt AC system ONLY. An approved 12 VAC
transformer (sold separately) must be used. If a Junction Box is
used, it would be for 12 VAC connections. Never wire the
ColorVision light directly to high voltage lines.
INSTALLING THE GLOBRITE
®
LIGHT ASSEMBLY
(AFTER NICHE INSTALLATION)