Pentair CFIGGEN20 Скачать руководство пользователя страница 26

 

 

24 

4.  The  warranty  contains  the  following  exclusions.  O-Rings,  rubber 
gaskets,  electrical  fuses,  and  circuit-breaker  components  are  normal 
replacement  items  subject  to  wear  and  are  excluded  from  the  warranty. 
Product  discoloration,  or  any  other  cosmetic  or  superficial  damage  or 
deterioration, regardless of its cause, is not covered by this warranty. The 
warranty is not applicable to problems arising from circumstances outside 
the control of Products, including, but not limited to the following: 
 
A. Damage or premature wear due to improper pool chemistry, and failure 
to maintain pool water chemistry in accordance with the recommendations 
contained in the owner's manual. 
B.  Damage  due  to  improper  installation  or  connection  to  improper 
voltages, including materials and workmanship supplied by others. 
C. Damage due to negligence or failure to properly maintain equipment, 
including the maintenance of clean and tight electrical connections. 
D.  Damage  due  to  improper  service,  as  well  as  unauthorized  equipment 
modifications and use of non-genuine replacement parts. 
E. Damage due to misapplication, misuse, abuse, overuse the cell lifetime 
(over 10 hours per day) or failure to operate equipment as specified in the 
owner's manual. 
F.  Problems  resulting  from  tampering,  accident,  fire,  flood,  freezing, 
lightning, insects, or other natural elements, or other circumstances beyond 
the control of Products. 
G.  Damage  due  to  over-tightening  of  threaded  components  or  excessive 
pressure or stress. 
H. Material supplied or workmanship performed by others in the process 
of installation.  
 
The  liability  of  Products  shall  not  exceed  the  repair  or  replacement  of 
defective items or parts under the referenced limited warranty terms. There 
are  no  implied  warranties  of  merchantability  or  fitness  for  a  particular 
purpose  that  apply  to  this  equipment.  Under  no  circumstances  shall 
Products,  its  agents,  employees,  and  affiliates  be  liable  for  any  loss, 
damage, injury, inconvenience or loss of time, incidental expenses such as 
labor  and  material  charges,  or  any  other  incidental,  or  consequential 
damages,  which  may  result  from  the  use,  installation,  removal,  or 
reinstallation of its equipment and parts. 
 
This warranty is valid only in the United States of America. This warranty 
gives you specific legal rights and you may also have other rights, which 
vary from state to state. This warranty supersedes all previous publications. 
Any dispute between the original purchaser and Products will be settled by 

Содержание CFIGGEN20

Страница 1: ...SALT CHLORINE GENERATOR USER S MANUAL CFICGEN20 CFICGEN40 CFICGEN60...

Страница 2: ...tents Important Safety Instructions 1 Water chemistry 2 Introduction Salt Chlorinator 9 Installation 11 LED Light Instruction 13 Operation 14 Maintenance 16 Installation 19 Troubleshooting 21 Warranty...

Страница 3: ...salt system works ATTN We are not affiliated with Pentair Pool Products The use of above trademarks herein is for informational purposes only READ AND FOLLOW ALL INSTRUCTIONS Disconnect all the AC po...

Страница 4: ...f a pool it is best to super chlorinate using an outside source i e use a shock treatment available at your local pool supplier Chloramines should not be present in pool water Chloramines are formed w...

Страница 5: ...phosphates While a 0 ppm level of nitrates is ideal the pool owner should make sure that nitrates DO NOT exceed 10 ppm IDEAL WATER CHEMISTRY LEVEL Voltage input 230VAC 115VAC PH 7 2 7 8 Calcium Hardne...

Страница 6: ...refore the pool owner must always test salt levels before adding salt A handheld meter calibrated for NaCl salt can be used to determine the salt levels of the water The LED Lights will give info on t...

Страница 7: ...le at 100 ppm cyanuric acid the correction amounts to 33 ppm 100 3 33 3 T i Calcium Hardness Ci Total Alkalinit y Ai 12 53 0 3 75 100 125 150 200 250 300 400 600 800 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2...

Страница 8: ...perse throughout the pool ABOVE GROUND POOLS WITHOUT MAIN DRAINS Add directly into the pool Brush the salt to speed up the dissolving process to not allow the salt to sit in a pile on the bottom of th...

Страница 9: ...7 POUNDS and Kg OF SALT NEEDED FOR 3400 PPM...

Страница 10: ...8 Amount of stabilizer cyanuric acid needed to obtain 40 ppm in pool The cyanuric acid should be at 30 50 ppm...

Страница 11: ...ing only a mild residual in the pool In addition the Electrolytic Cell continuously shocks the incoming water burning off any oils organic matter or other particles that need to be oxidized Best of al...

Страница 12: ...d in the enclosure for additional protection For information about installing and proper use of the Power Center see the CFICGEN installation WARNING CHLORINE GAS BUILDUP CAN OCCUR WITH IMPROPER WIRIN...

Страница 13: ...flow rates over 80 GPM include those that have in floor cleaning systems or booster pumps These systems must use a bypass loop with the CFICGEN with a flow control valve that assures that the flow thr...

Страница 14: ...Size liters of water in your pool Rectangular Pools Length x width meters x average depth x 1000 Circular Pools Diameter x diameter x average depth x 785 Oval Pools Length x width meters x average de...

Страница 15: ...y 2800 PPM to 4500 PPM INSPECT SALT RED ON Salt Level below 2300 PPM or above 6000 PPM INSPECT SALT RED flashing Salt Level 2300 PPM to 2800 PPM 4500 PPM to 6000 PPM CELL GOOD LED ON The cell is good...

Страница 16: ...l or spa water It is the pool owner s responsibility for monitoring and maintaining free chlorine levels at 2 0 to 4 0 parts per million ppm according to APSP recommendations It is the pool owner s re...

Страница 17: ...ee chlorine demand of pool water it may take a few days to determine the number of daily pool operating hours and Sanitizer Output percentage setting for your pool Continue adjusting as necessary allo...

Страница 18: ...f chlorine may cause excessive corrosion of metal components and possibly cause damage to associated pool equipment Monthly Service To ensure that the correct chemical balance is maintained in your po...

Страница 19: ...ng feature cell plate reversal that helps remove scale deposits from the CFICGEN blades Note Automatic cleaning does not interrupt chlorine production Scale is a white crusty deposit that forms in exc...

Страница 20: ...he solution until the foaming has stopped However do not leave acid in the CFICGEN for more than thirty 30 minutes Excessive acid washing will damage the blades Remove the CFICGEN from the bucket and...

Страница 21: ...ead and follow Safety Instructions Wiring should only be performed by a qualified professional Install the CFICGEN unit a minimum of three 3 feet away from the heater outlet Pipe couplings Schedule 80...

Страница 22: ...switched OFF before connecting the power cord to the Power Center 2 Align the three 3 pins of the cell power cord connector with the socket on the top of the Power 3 Center and insert the connector T...

Страница 23: ...try was not balanced prior to system installation and a high chlorine demand persists Contact pool professional ensure all chemicals on p 6 are within range chemically shock pool if necessary Red Insp...

Страница 24: ...cell failure Cell never or rarely has mineral buildup Water may be corrosive due to imbalanced water chem and a low Saturation Index Ensure that your Saturation Index is at or near zero to avoid dama...

Страница 25: ...e same perfect new condition Cleared Payment via PayPal must be received within 3 days of transaction and prior to shipping For Commercial use any pool that is not for private single family use or the...

Страница 26: ...ver 10 hours per day or failure to operate equipment as specified in the owner s manual F Problems resulting from tampering accident fire flood freezing lightning insects or other natural elements or...

Страница 27: ...r authorized agents installers be responsible for consequential special or incidental damage s of any kind including but not limited to personal injury Property damage or damage to or loss of equipmen...

Отзывы: