Troubleshooting
Problem
POSSIBLE CAUSE:
SUGGESTED
ACTION:
Low or no chlorine
residual in pool
Sanitizer Output percentage set too low or off at 0%
Increase Output
Level.
Insufficient run time
Increase run time
to at least 1 hour
per 10° ambient
temp.
Heavy pool use, inclement weather, organic matter
Activate Super CL
mode
or
chemically shock
pool.
Water chemistry issues:
Low Chlorine Stabilizer
Low salt in the pool (less than 2300 ppm)
Phosphates in pool
Nitrates in pool
Contact
pool
professional,
ensure
all
chemicals
The cell is dirty, clogged, or
Has excessive scaling or mineral build-up
Remove Cell from
plumbing, inspect
and clean (see
p.13).
Low or no Chlorine
residual in pool
after recent
installation
Water chemistry was not balanced prior to system installation
and a high chlorine demand persists
Contact
pool
professional,
ensure
all
chemicals on p.6
are within range,
chemically shock
pool if necessary.
Red Inspect cell Led
is on
It is time to clean the Electrolytic Cell.
The Cell must be
cleaned
Cell efficiency has been greatly reduced
Inadequate water
flow exists, or Cell
must be replaced.
Red Inspect Salt
LED is on
Pool water salt is too low or too high, system is off. Less than
2300 or Over 6000 ppm
Correct
the
salinity level.
Red Inspect Salt Led
is flashing
Pool water salt is low or high,
2300 PPM to 2500 PPM/4500
PPM to 6000 PPM
2300-2500, the system is still working
Correct
the
salinity level.
No Power
Fuse/Reset has tripped
Check fuses on
power center
No AC Power to the power center
Check
the
connection
No Flow LED is on
Incorrect installation
Verify
Sensor
probe
correct
orientation
Sensor probe
Ensure
correct