LEVEL IV VIEWING HISTORY
H Values
Historical information can be viewed by pressing the SET and
DOWN buttons simultaneously, with the 764 control in the
home position. Release both buttons when the control displays
an “H” value. Press the UP or DOWN buttons to navigate to
each setting.
Table 5 History Data
H#
Description
Range
Notes
H0*
Initial Setting Value
Cubic Feet or Liters
Resin Volume
H1
Days since last regeneration
0-255
H2
Current Flow Rate
Depends on turbine used
H3
Water used today in gallons or m
3
since Time of Regeneration 0-131,070 gallons or
0-1,310.70 m
3
H4
Water used since last regeneration in gallons or m
3
0-131,070 gallons or
0-1,310.70 m
3
H5*
Total water used since reset in 100s
0-999900 gallons or
0-9999 m
3
H6*
Total water used since reset in 1,000,000
4,294 x 10
6
gallons or
4,264 x 10
4
m
3
H7
Average usage for Sunday in gallons or m
3
0-131,070 gallons or
0-1,310.70 m
3
H8
Average usage for Monday in gallons or m
3
0-131,070 gallons or
0-1,310.70 m
3
H9
Average usage for Tuesday in gallons or m
3
0-131,070 gallons or
0-1,310.70 m
3
H10
Average usage for Wednesday in gallons or m
3
0-131,070 gallons or
0-1,310.70 m
3
H11
Average usage for Thursday in gallons or m
3
0-131,070 gallons or
0-1,310.70 m
3
H12
Average usage for Friday in gallons or m
3
0-131,070 gallons or
0-1,310.70 m
3
H13
Average usage for Saturday in gallons or m
3
0-131,070 gallons or
0-1,310.70 m
3
H14
Average service cycle
0-255 days
H15*
Peak Flow Rate
0-200 gpm or
1000 Lpm
H16
Day and Time of Peak Flow Rate
Time and day that peak flow occurred
H17*
Months since service
0-2,184 months
H18
Water used since last regeneration - Tank 1
0-131,070 gallons or
0-1,310.70 m
3
H19*
Water used since last regeneration - Tank 2
0-131,070 gallons or
0-1,310.70 m
3
Hr
Number of regenerations since last service
0-65536
* H0, H5, H6, H15, H17, H19 values can be reset by pressing and holding
for three seconds while the value is being displayed.
20
•