TEMPERATURE SETTING
The heater comes factory set at 78° F for the pool mode and 100° F for the spa mode. Using the up and down arrows, you
can set the thermostats to a minimum temperature of 65° F, or a maximum of 104° F. If you desire to heat only one body
of water, the thermostat is capable of an off mode. As an example, if you only wish to heat the spa and not the pool, simply
depress and hold the pool down arrow, and the thermostat will lower its setting to 65° F then go to an off mode.
MAXIMUM TEMPERATURE SET POINT
1. Unbolt and remove the upper jacket halves (see
Figure 35
).
2. Pull hair pin clips.
3. Press the clips and remove the control panel board dome. Locate the yellow
button on the corner of the control board.
4. Push the
Max. Temp. Set Point
button on the back of the control board
(see
Figure 36
).
The following sequence should happen:
A. The unit will come on and the
POOL ON
light will come on.
B. Press the
V
TEMP
or
W
TEMP
pad (on TOP of the panel) to set
maximum pool temperature.
C. Wait up to 30 seconds; the
POOL ON
light will go off and the
SPA ON
light will come on. To override the time delay, push the
Max. Temp. Set Point
button again.
D. Press the
V
TEMP
or
W
TEMP
button on the control panel
and set maximum spa temperature to 104°F (40°C) or less.
E. Wait up to 30 seconds; the
SPA ON
light will go off and
the unit will shut down. To override the time delay, push
the
Max. Temp. Set Point
button again.
5. Reinstall and bolt up the upper jacket halves.
Section 3. Operation
S1
SET
M A
X
S1
SET
M A
X
Figure 36.
1
2
AUX
2
HIGH SPE
ED
LOW SPE
ED
BOOSTER
PUMP
Clips
Figure 35.