READ AND FOLLOW SAFETY INSTRUCTIONS!

 This is the safety alert symbol. When you see this symbol 

on your pump or in this manual, look for one of the following 
signal words and be alert to the potential for personal injury:

 warns about hazards that will cause serious 

personal injury, death or major property damage if ignored. 

 warns about hazards that can cause serious 

personal injury, death or major property damage if ignored.

 warns about hazards that will or can cause minor 

personal injury or property damage if ignored.

NOTICE:

 indicates special instructions which are important but 

not related to hazards.
•  Carefully read and follow all safety instructions in this manual 

and on pump.

•  Keep safety labels in good condition. 
•  Replace missing or damaged safety labels.
•  Make workshops childproof; use padlocks and master 

switches; remove keys.

 Read carefully the product installation & 

operation instructions. Failure to follow the instructions and 
warnings in the manual may result in serious or fatal injury 
and/or property damage, and will void the product warranty. 
This product must be installed by a qualified professional. 
Follow all applicable local and state codes and regulations. In 
the absence of such codes, follow the current editions of the 
National Plumbing Code and National Electrical Code (NEC), as 
applicable.

 This product is used in conjunction with a 

system containing a tank under pressure, which may over time 
corrode, weaken and burst or explode, causing serious or fatal 
personal injury, leaking or flooding and/or property damage. 
To minimize risk, a licensed professional must install and 
periodically inspect and service the product and system. A drip 
pan connected to an adequate drain must be installed if leaking 
or flooding may cause  property damage. Do not locate system 
in an area where leaking may cause property damage.

 This control is capable of running pumps 

to pressures that may exceed the limitations of system 
components. Never set the operating pressure higher than that 
of the safe system capacity.

 This control can be adjusted to a narrow 

pressure differential. An improperly sized tank can cause the 
pump to cycle and lead to pump damage. This may require a 
larger pressure tank than is normally used.

CALIFORNIA PROPOSITION 65 WARNING

 This product and related accessories contain 

chemicals known to the State of California to cause cancer, 
birth defects or other reproductive harm.

ELECTRICAL SAFETY

 

ELECTROCUTION HAZARD: 

Must be installed by 

a qualified professional. First disconnect all electrical power 
before attempting service. For your safety, the installation and 
operation instructions must be followed to minimize the risk of 
electric shock, property damage or personal injury.

GENERAL SAFETY

 Do not touch an operating motor. Modern 

motors can operate at high temperatures. To avoid burns when 
servicing pump, allow it to cool for 20 minutes after shutdown 
before handling.
•  Do not allow pump or any system component to freeze. To do 

so will void the warranty. See “Warranty” on Page 10.

•  Pump only water with this pump.
•  Periodically inspect pump and system components.
•  Wear safety glasses at all times when working on pumps.
•  Keep work area clean, uncluttered and properly lighted. 

Store all unused tools and equipment.

•  Keep visitors at a safe distance from the work areas.

 Pump body may explode if used as a booster 

pump unless a relief valve capable of passing full pump flow at 
75 psi is installed.

 A water test must be taken before installation 

of any water treatment equipment. The water quality can 
significantly influence the life of your system. You should 
test for corrosive elements, acidity, total solids and other 
relevant contaminants, including chlorine and treat your water 
appropriately to ensure satisfactory performance and prevent 
premature failure.

 Use only lead-free solder and flux for all  

sweat-solder connections, as required by state and federal 
codes.
 

 

EXPLOSION OR RUPTURE HAZARD: 

A relief 

valve must be installed to prevent pressure in excess of local 
code requirement or maximum working pressure designated in 
the product manual, whichever is less. Do not expose system 
to freezing temperatures or temperatures in excess of 120°F 
(49°C). Failure to properly size the system or follow instructions 
in the manual may result in excessive strain on the system and 
may lead to product failure, leakage, flooding and/or property 
damage.

GENERAL INFORMATION

Содержание C4S(X)P Series

Страница 1: ...03 557 01 23 20 Part 056255571 INSTALLATIONAND OPERATIONMANUAL SUBMERSIBLESOLIDSHANDLINGPUMP C4S X P H3H X P H4H X P S4M X P S4P X P S4HV X P S4MV X P Used in Hazardous Locations Class I Division I G...

Страница 2: ...ENTS SECTION PAGE General Information 3 4 Pump Installation 5 Pump Operation Maintenance 6 7 Parts List 8 Hydraulic Ends Part List 9 Motor Parts Group 10 Impeller Parts List 10 11 Wiring Diagrams 12 W...

Страница 3: ...l An improperly sized tank can cause the pump to cycle and lead to pump damage This may require a larger pressure tank than is normally used CALIFORNIA PROPOSITION 65 WARNING This product and related...

Страница 4: ...nding temperature the starter in the panel breaks power to the pump Once the sensor resets the starter is automatically reset for FM for continued operation of the pump This circuitry is supplied in a...

Страница 5: ...any other voltage TO RE WIRE THE PUMP FROM 230V TO 460V 3 PHASE Only a 230V pump from the factory is considered dual voltage a cord label clearly states the factory wound voltage 1 Remove all six 7 ca...

Страница 6: ...le motors that are out of warranty can be serviced in the field by any reliable motor service shop Any pump that is in warranty must be returned to the factory for service or repaired at an authorized...

Страница 7: ...ity 1 Discharge gate valve may be partially closed or partially clogged 2 Check valve may be partially clogged Raise level up and down to clear 3 Pump may be running in wrong direction Low speed pumps...

Страница 8: ...78190103 SEAL PLATE S4P X P H3H X P H4H X P C4S X P 1 B6 07597A017 BOLT SEAL PLATE S4M X P S4MV X P S4HV X P 4 047560061 BOLT SEAL PLATE S4P X P H3H X P H4H X P C4S X P 4 Ref No Part No Part Descripti...

Страница 9: ...21 005680021 005680021 005680191 D9 CHOPPER PLATE N A N A N A N A N A N A 153340002 D10 CHOPPER BLADE N A N A N A N A N A N A 153320002 D11 RETAINER PLATE N A N A N A N A N A N A 153330001 D12 SCREW C...

Страница 10: ...5102 H3H X P500DC 5 208 3 10 4 7 50 151465102 H3H X P500EC 5 230 3 10 4 7 50 151465102 H3H X P500FC 5 460 3 10 4 7 50 151465102 H3H X P500GC 5 575 3 10 4 7 50 151465102 H3H X P750CC 7 5 230 1 8 4 8 00...

Страница 11: ...C4S X P750DC 7 5 208 3 8 4 7 153310192 C4S X P750EC 7 5 230 3 8 4 7 153310192 C4S X P750FC 7 5 460 3 10 4 7 153310192 C4S X P750GC 7 5 575 3 10 4 7 153310192 C4S X P1000DC 10 208 3 8 4 7 153310192 C4S...

Страница 12: ...CAN ONLY BE CONNECTED TO PANEL TERMINAL BLOCKS AS SHOWN ON SCHEMATIC INCORRECT CONNECTION CAN CAUSE DAMAGE TO PUMP AND OR PANEL COMPONENTS THREE PHASE OVERLOAD RELAY MUST BE CLASS 1O TRIP AMBIENT COMP...

Страница 13: ...ll not apply a to defects or malfunctions resulting from failure to properly install operate or main tain the unit in accordance with the printed instructions provided b to failures resulting from abu...

Страница 14: ...14 E 03 577 01 23 20 NOTES...

Страница 15: ...15 E 03 577 01 23 20 NOTES...

Страница 16: ...and unregistered trademarks and logos are the property of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications wi...

Отзывы: