background image

11

  

E-03-577 (01-23-20)

IMPELLER PARTS LIST

S4M(X)P 

S4HV(X)P

S4P(X)P

C4S(X)P

S4MV(X)P 

Description

HP

Voltage/PH

Cord

Trim

Impeller

  1750 RPM

S4M(X)P500BC

5

208/1

8-4

6.75

070710312

S4M(X)P500CC

5

230/1

8-4

6.75

070710312

S4M(X)P500DC

5

208/3

10-4

6.75

070710312

S4M(X)P500EC

5

230/3

10-4

6.75

070710312

S4M(X)P500FC

5

460/3

10-4

6.75

070710312

S4M(X)P500GC

5

575/3

10-4

6.75

070710312

S4M(X)P750CC

7.5

230/1

8-4

7.63

070710442

S4M(X)P750DC

7.5

208/3

8-4

7.63

070710442

S4M(X)P750EC

7.5

230/3

8-4

7.63

070710442

S4M(X)P750FC

7.5

460/3

10-4

7.63

070710442

S4M(X)P750GC

7.5

575/3

10-4

7.63

070710442

S4M(X)P1000DC

10

208/3

8-4

8.13

070710202

S4M(X)P1000EC

10

230/3

8-4

8.13

070710202

S4M(X)P1000FC

10

460/3

10-4

8.13

070710202

S4M(X)P1000GC

10

575/3

10-4

8.13

070710202

S4M(X)P1500DC

15

208/3

8-4

8.63

070710172

S4M(X)P1500EC

15

230/3

8-4

8.63

070710172

S4M(X)P1500FC

15

460/3

8-4

8.63

070710172

S4M(X)P1500GC

15

575/3

10-4

8.63

070710172

  1150 RPM

S4M(X)P300DB

3

208/3

10-4

7.75

070710062

S4M(X)P300EB

3

230/3

10-4

7.75

070710062

S4M(X)P300FB

3

460/3

10-4

7.75

070710062

S4M(X)P300GB

3

575/3

10-4

7.75

070710062

S4M(X)P500DB

5

208/3

10-4

8.75

070710022

S4M(X)P500EB

5

230/3

10-4

8.75

070710022

S4M(X)P500FB

5

460/3

10-4

8.75

070710022

S4M(X)P500GB

5

575/3

10-4

8.75

070710022

Description

HP

Voltage/PH

Cord

Trim

Impeller

  1750 RPM

S4P(X)P500BC

5

208/1

8-4

6.5

137226152

S4P(X)P500CC

5

230/1

8-4

6.5

137226152

S4P(X)P500DC

5

208/3

10-4

6.5

137226152

S4P(X)P500EC

5

230/3

10-4

6.5

137226152

S4P(X)P500FC

5

460/3

10-4

6.5

137226152

S4P(X)P500GC

5

575/3

10-4

6.5

137226152

S4P(X)P750CC

7.5

230/1

8-4

7.75

137226102

S4P(X)P750DC

7.5

208/3

8-4

7.75

137226102

S4P(X)P750EC

7.5

230/3

8-4

7.75

137226102

S4P(X)P750FC

7.5

460/3

10-4

7.75

137226102

S4P(X)P750GC

7.5

575/3

10-4

7.75

137226102

S4P(X)P1000DC

10

208/3

8-4

8.63

137226162

S4P(X)P1000EC

10

230/3

8-4

8.63

137226162

S4P(X)P1000FC

10

460/3

10-4

8.63

137226162

S4P(X)P1000GC

10

575/3

10-4

8.63

137226162

S4P(X)P1500DC

15

208/3

8-4

9.63

137226182

S4P(X)P1500EC

15

230/3

8-4

9.63

137226182

S4P(X)P1500FC

15

460/3

8-4

9.63

137226182

S4P(X)P1500GC

15

575/3

10-4

9.63

137226182

Description

HP

Voltage/PH

Cord

Trim

Impeller

  1750 RPM

C4S(X)P750CC

7.5

230/1

8-4

7

153310192

C4S(X)P750DC

7.5

208/3

8-4

7

153310192

C4S(X)P750EC

7.5

230/3

8-4

7

153310192

C4S(X)P750FC

7.5

460/3

10-4

7

153310192

C4S(X)P750GC

7.5

575/3

10-4

7

153310192

C4S(X)P1000DC

10

208/3

8-4

7

153310192

C4S(X)P1000EC

10

230/3

8-4

7

153310192

C4S(X)P1000FC

10

460/3

10-4

7

153310192

C4S(X)P1000GC

10

575/3

10-4

7

153310192

C4S(X)P1500DC

15

208/3

8-4

8.5

153310072

C4S(X)P1500EC

15

230/3

8-4

8.5

153310072

C4S(X)P1500FC

15

460/3

8-4

8.5

153310072

C4S(X)P1500GC

15

575/3

10-4

8.5

153310072

  1150 RPM

C4S(X)P300DB

3

208/3

10-4

7.25

153310172

C4S(X)P300EB

3

230/3

10-4

7.25

153310172

C4S(X)P300FB

3

460/3

10-4

7.25

153310172

C4S(X)P300GB

3

575/3

10-4

7.25

153310172

C4S(X)P500DB

5

208/3

10-4

8.88

153310122

C4S(X)P500EB

5

230/3

10-4

8.88

153310122

C4S(X)P500FB

5

460/3

10-4

8.88

153310122

C4S(X)P500GB

5

575/3

10-4

8.88

153310122

Description

HP

Voltage/PH

Cord

Trim

Impeller

 3450  RPM

S4HV(X)P750DD

7.5

208/3

8-4

4.63

082130172

S4HV(X)P750ED

7.5

230/3

8-4

4.63

082130172

S4HV(X)P750FD

7.5

460/3

10-4

4.63

082130172

S4HV(X)P750GD

7.5

575/3

10-4

4.63

082130172

S4HV(X)P1000DD

10

208/3

8-4

5

082130042

S4HV(X)P1000ED

10

230/3

8-4

5

082130042

S4HV(X)P1000FD

10

460/3

10-4

5

082130042

S4HV(X)P1000GD

10

575/3

10-4

5

082130042

Description

HP Voltage/PH

Cord

Trim

Impeller

  1750 RPM

S4MV(X)P500BC

5

208/1

8-4

6.5

070810332

S4MV(X)P500CC

5

230/1

8-4

6.5

070810332

S4MV(X)P500DC

5

208/3

10-4

6.5

070810332

S4MV(X)P500EC

5

230/3

10-4

6.5

070810332

S4MV(X)P500FC

5

460/3

10-4

6.5

070810332

S4MV(X)P500GC

5

575/3

10-4

6.5

070810332

S4MV(X)P750CC

7.5

230/1

8-4

7.38

070810072

S4MV(X)P750DC

7.5

208/3

8-4

7.38

070810072

S4MV(X)P750EC

7.5

230/3

8-4

7.38

070810072

S4MV(X)P750FC

7.5

460/3

10-4

7.38

070810072

S4MV(X)P750GC

7.5

575/3

10-4

7.38

070810072

S4MV(X)P1000DC

10

208/3

8-4

8

070810022

S4MV(X)P1000EC

10

230/3

8-4

8

070810022

S4MV(X)P1000FC

10

460/3

10-4

8

070810022

S4MV(X)P1000GC

10

575/3

10-4

8

070810022

S4MV(X)P1500DC

15

208/3

8-4

8.75

070810092

S4MV(X)P1500EC

15

230/3

8-4

8.75

070810092

S4MV(X)P1500FC

15

460/3

8-4

8.75

070810092

S4MV(X)P1500GC

15

575/3

10-4

8.75

070810092

  1150 RPM

S4MV(X)P300DB

3

208/3

10-4

7.75

070810102

S4MV(X)P300EB

3

230/3

10-4

7.75

070810102

S4MV(X)P300FB

3

460/3

10-4

7.75

070810102

S4MV(X)P300GB

3

575/3

10-4

7.75

070810102

S4MV(X)P500DB

5

208/3

10-4

8.75

070810092

S4MV(X)P500EB

5

230/3

10-4

8.75

070810092

S4MV(X)P500FB

5

460/3

10-4

8.75

070810092

S4MV(X)P500GB

5

575/3

10-4

8.75

070810092

Содержание C4S(X)P Series

Страница 1: ...03 557 01 23 20 Part 056255571 INSTALLATIONAND OPERATIONMANUAL SUBMERSIBLESOLIDSHANDLINGPUMP C4S X P H3H X P H4H X P S4M X P S4P X P S4HV X P S4MV X P Used in Hazardous Locations Class I Division I G...

Страница 2: ...ENTS SECTION PAGE General Information 3 4 Pump Installation 5 Pump Operation Maintenance 6 7 Parts List 8 Hydraulic Ends Part List 9 Motor Parts Group 10 Impeller Parts List 10 11 Wiring Diagrams 12 W...

Страница 3: ...l An improperly sized tank can cause the pump to cycle and lead to pump damage This may require a larger pressure tank than is normally used CALIFORNIA PROPOSITION 65 WARNING This product and related...

Страница 4: ...nding temperature the starter in the panel breaks power to the pump Once the sensor resets the starter is automatically reset for FM for continued operation of the pump This circuitry is supplied in a...

Страница 5: ...any other voltage TO RE WIRE THE PUMP FROM 230V TO 460V 3 PHASE Only a 230V pump from the factory is considered dual voltage a cord label clearly states the factory wound voltage 1 Remove all six 7 ca...

Страница 6: ...le motors that are out of warranty can be serviced in the field by any reliable motor service shop Any pump that is in warranty must be returned to the factory for service or repaired at an authorized...

Страница 7: ...ity 1 Discharge gate valve may be partially closed or partially clogged 2 Check valve may be partially clogged Raise level up and down to clear 3 Pump may be running in wrong direction Low speed pumps...

Страница 8: ...78190103 SEAL PLATE S4P X P H3H X P H4H X P C4S X P 1 B6 07597A017 BOLT SEAL PLATE S4M X P S4MV X P S4HV X P 4 047560061 BOLT SEAL PLATE S4P X P H3H X P H4H X P C4S X P 4 Ref No Part No Part Descripti...

Страница 9: ...21 005680021 005680021 005680191 D9 CHOPPER PLATE N A N A N A N A N A N A 153340002 D10 CHOPPER BLADE N A N A N A N A N A N A 153320002 D11 RETAINER PLATE N A N A N A N A N A N A 153330001 D12 SCREW C...

Страница 10: ...5102 H3H X P500DC 5 208 3 10 4 7 50 151465102 H3H X P500EC 5 230 3 10 4 7 50 151465102 H3H X P500FC 5 460 3 10 4 7 50 151465102 H3H X P500GC 5 575 3 10 4 7 50 151465102 H3H X P750CC 7 5 230 1 8 4 8 00...

Страница 11: ...C4S X P750DC 7 5 208 3 8 4 7 153310192 C4S X P750EC 7 5 230 3 8 4 7 153310192 C4S X P750FC 7 5 460 3 10 4 7 153310192 C4S X P750GC 7 5 575 3 10 4 7 153310192 C4S X P1000DC 10 208 3 8 4 7 153310192 C4S...

Страница 12: ...CAN ONLY BE CONNECTED TO PANEL TERMINAL BLOCKS AS SHOWN ON SCHEMATIC INCORRECT CONNECTION CAN CAUSE DAMAGE TO PUMP AND OR PANEL COMPONENTS THREE PHASE OVERLOAD RELAY MUST BE CLASS 1O TRIP AMBIENT COMP...

Страница 13: ...ll not apply a to defects or malfunctions resulting from failure to properly install operate or main tain the unit in accordance with the printed instructions provided b to failures resulting from abu...

Страница 14: ...14 E 03 577 01 23 20 NOTES...

Страница 15: ...15 E 03 577 01 23 20 NOTES...

Страница 16: ...and unregistered trademarks and logos are the property of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications wi...

Отзывы: