5) Seal around edge of vent pipe inner tube.
6) Slide the adapter sleeve back onto adapter and tighten the gear clamps to complete the
connection.
7) If the vent requires cutting to length, a fine toothed hacksaw can be used. Remove any burrs and
flare out the end of the inner vent tube for easy installation of the adapter.
Figure 12
Installing The Outside Terminal
Using
Figure 14
and
Figure 15
complete the following steps:
1) Determine the terminal location.
2) Cut 8-1/4” diameter hole through
the wall (slightly larger than the O.D.
of the terminal).
3) Pull apart the inner and the outer
terminal sections.
4) Slide the outer wall plate over the
outer section of the terminal until it
rests against the bead.
5) From the outside of the building,
insert the outer section through the
hole until it rests against the wall.
6) From the inside of the building,
Figure 13
slide the inner wall plate over the outer section and secure using four (4) screws.
7) Position the outer section so the seam on the flue collar is on the top and the air intake on the
bottom. Secure the outer section by tightening the gear clamp around it. The gear clamp is factory
welded to the inner wall plate.