CONNECTIONS TO THE OUTSIDE TERMINAL
FIGURES 16 and 17
Provide an illustration of the steps outlined below to connect to the outside
terminal. Follow the steps outlined here to accomplish this task.
-
Slide the inner section over the vent pipe.
-
Connect the terminal adapter to the vent pipe directed in the joint assembly section of this
manual
-
Apply a bead of sealant around the terminal flue collar.
-
Slide the appliance adapter over the flue collar.
-
Tighten the terminal adapter gear clamp around the flue collar.
-
Seal the adapter seam with sealant.
-
Slide the inner section over the outer section and secure by tightening the gear clamp.
-
Stretch the air intake flex to the desired length and slide it over the air intake collar. Seal the
connection with aluminum tape and secure it using the air intake clamp. The beaded end of the
air intake clamp should go first over the air intake collar.
-
Seal the gap between the vent pipe and the inner section with silicone sealant.
Apply z flex sealant
Figure 17