21
Get Temperature
(Temperature range -25 to 80 degrees C)
You can text and get the current temperature at any time.
Command: Temp
The system responds with:
The temperature is xx Degrees (where xx is the temperature is degrees C)
Set alarm temperatures
(see page 25 for details)
Both low and high alarm levels can be set, the unit will text you when the level has been
reached.
Command: Set temp yyy alarm to xxx degrees
(where yyy is either high or low, xx is the temperature) Note is a minus temperature is
required place the
– symbol before the temperature. E.g
Set temp yyy alarm to -20 degrees
The system responds with:
The temperature yyy alarm has been set to xxxx degrees and the alarm has been
turned On
(where yyy will be either low or high depending on the above)
Set alarm reset temperatures
Both low and high alarm temperatures will be automatically reset approx. 3 degrees above or
below the temperatures depending on if the alarm is low or high OR the reset levels can be
programmed.
Command: Set temp yyy reset to xxx degrees
(where yyy is either high or low, xx is the temperature) Note is a minus temperature is
required place the
– symbol before the temperature. E.g
Set temp yyy alarm to -20 degrees
The system responds with:
The yyy temp alarm reset temperature has been set to xxxx degrees
(where yyy will be either low or high depending on the above)
Turning temperature alarms On / Off
The temperature alarms can be turned On or Off.
Command: Temp xxxx alarm yy (xxxx can be the word low or high : yy can be on or off)
e.g Temp high alarm off
The system responds with:
The temperature xxx alarm has been turned yy, (where yy is either on or off)
Ezy Switch SMS-TEMP-4 Installation & Operation