16
Make an Output pulse On and Off
Command:
Make OUTPUT NAME pulse XX secs
This sets the output pulse time, XX can be between 1 and 99 seconds
When the Output ON command is sent as follows:
Turn OUTPUT NAME On
The Output will turn On for the programmed pulse time and then turn Off, the system
responds with:
OUTPUT NAME has been pulsed on and off
If you try and set an Input as a pulse Output, the system responds with:
Sorry pulses only apply to outputs, please check the name and try again
If the Output is already a pulsed Output the system responds with:
OUTPUT NAME is already a pulsed output so does not need changing
If the Output is initially off and everything goes correct, the system responds with:
OUTPUT NAME is now a pulsing output
If the pulse time has not been set as per above the defalt time is 3 seconds and the system
responds with:
OUTPUT NAME is now a pulsing output with a defalt pulse time of 3 seconds
If the Output was initially On when the Output was set, the system responds with:
OUTPUT NAME is now a pulsing output and has been turned off in preparation for use
If the Output is linked to an Input, when the Input is triggered the system sends:
INPUT NAME linked output OUTPUT NAME has been pulsed on then off
Clear Output pulse (make output non pulsing)
Command:
Clear OUTPUT NAME pulse
If you try to clear a pulsed Output when it is not set, the system responds with:
OUTPUT NAME is not currently a pulsed output so does not need changing
If you try and clear a pulse on an Input, the system responds with:
Sorry pulse only apply to outputs, please check the name and try again
Otherwise if its all ok, the system responds with:
OUTPUT NAME is no longer a pulsing output
Ezy Switch SMS-TEMP-4 Installation & Operation