Disconnecting
Push in Collet and Remove Tubing
- To disconnect, ensure the system is depressur-
ized before removing the tube, Push in the collet squarely against the face of the fitting.
With the collet held in this position, the tube can be removed. The fitting can be re-used.
Should a leak occur at a fitting, the cause is generally defective tubing. To fix a leak, re-
lieve pressure, release tubing, cut off at least 1/4" from the end (square cut), reattach the
tubing, and confirm the connection is leak free. Each time a new connection is made, it is
advisable to cut off 1/4" from the end of the tubing using these fittings.