PWARO-XXXX-P

Содержание 200-PWARO Series

Страница 1: ...Penguin Water Reverse Osmosis System 200 PWRO XXXX 200 PWRO XXXX P 200 PWARO XXXX 200 PWARO XXXX P...

Страница 2: ...tallation 15 Initial Tubing Connections 16 RO Unit Installation 16 Final Tubing Connections 16 System Start Up 19 Prior to Start Up 19 Flushing System and Checking Operation 19 Air Purging 19 Maintena...

Страница 3: ...Parts Check List RO Module Tubing Bundle Filter Wrench 1 4 Drain Saddle Tank Valve Angle Stop Feed Valve Tank and Side Mount Tank Stand Faucet Connector 3...

Страница 4: ...Pre and Post Filters Membrane Pre Installed Alkaline Filter Included with 6 Stage System 4...

Страница 5: ...nt the system typically below a sink Storage Tank Holds filtered water that is ready for use Automatic Shut Off Valve ASO Senses when the storage tank is full and closes the water supply to conserve w...

Страница 6: ...particular installation 3 8 Drill and 1 4 drill bit Faucet Drill Bit For standard faucets use a 7 16 drill bit For Air Gap faucets use a 7 8 minimum 1 1 8 maximum drill bit Phillips head and flat bla...

Страница 7: ...ee from score marks and that burrs and sharp edges be removed before inserting the tube into the fitting For soft thin walled tubing we recommend the use of tube inserts 2 Insert Tube The fittings wil...

Страница 8: ...this position the tube can be removed The fitting can be re used Should a leak occur at a fitting the cause is generally defective tubing To fix a leak re lieve pressure release tubing cut off at leas...

Страница 9: ...will be installed in the cold water line between the sink cold water shutoff valve and the sink faucet tubing Connect to a potable cold water supply line only NOTE Softened water is preferred since i...

Страница 10: ...nything Drill a 7 16 hole for non air gap faucets If an air gap faucet is being used drill a hole that is 7 8 minimum 1 1 8 maximum Be sure to use a drill bit compatible with your surface Clean up any...

Страница 11: ...8 QC faucet connector on the threaded nipple This fitting does not require sealant as it seals at the beveled sur face Tighten the fitting hand tight then use an adjustable wrench to tighten an addi t...

Страница 12: ...er in the installation 2 Now push a piece of 3 8 black tubing onto the larger brass barb on the bottom of the faucet Be sure the tube is completely pushed on the barb or a leak could occur Leave the o...

Страница 13: ...a towel to dry the water that is spilled Now install the angle stop valve on the sink faucet shutoff valve and tighten it Use two wrenches to hold the valve while tightening Don t worry about the ang...

Страница 14: ...ves are designed to be installed on standard 1 1 2 OD drain pipe Install the drain saddle valve above the trap between the sink and trap and on the vertical or horizontal tailpiece Never install a dra...

Страница 15: ...n saddle If using an air gap faucet connect the 3 8 black line from the larger brass barb to the drain saddle Tank Installation 1 Apply Teflon tape to the tank outlet threads 3 4 wraps will be suffici...

Страница 16: ...needed Drill holes for mounting screws then proceed to install the mounting screws Allow the mounting bracket slots to slip over them NOTE If the cabinet sidewalls are not solid the unit may sit on t...

Страница 17: ...ing Leave the tank valve closed 3 Connect the orange tubing from the angle stop supply valve to the RO unit at the sediment filter inlet fitting When facing the unit this is the far right sump Permeat...

Страница 18: ...meate pump run a length of tubing from the Brine Out port on the permeate pump to the drain saddle connection If an air gap faucet is being used and the system is equipped with a permeate pump run a l...

Страница 19: ...s The system is full when the water to the drain stops Check for leaks with the system full and repair them accordingly NOTE When the system is first turned on water may intermittently spurt from the...

Страница 20: ...the tank tubing 5 Once there is a steady stream coming from the tank tubing push it back into the tank valve Be sure to push it in the tank valve completely or a leak could occur 6 Turn the tank valv...

Страница 21: ...ery 6 12 Months 507 PWCB 2509 OR Second Sump Every 6 12 Months 507 PWCB 2509 CL OR Third Sump Every 6 12 Months 255 PWM 1812 XXX RO Membrane Every 3 5 Years 530 PW INLRO 14 B Carbon Post Filter Every...

Страница 22: ...ucet Allow the system to fill and rest for another 10 minutes Open the faucet again and allow the system to flush for another 10 minutes Shut off the inlet supply and open the faucet to depressurize t...

Страница 23: ...is purged from the system Flushing System and Checking Operation To make sure the RO system is operating correctly follow these simple procedures 1 Open the faucet handle and allow the tank to complet...

Страница 24: ...nside surfaces of tanks and hoses Filling the system with impure water can also be a cause but over time bacteria grows even in chlorina ted water When water sits in a tank or hose chlorine levels dro...

Страница 25: ...Standard Flow Diagram 25...

Страница 26: ...Permeate Pump Flow Diagram 26...

Страница 27: ...6 Stage RO Flow Diagram 27...

Страница 28: ...6 Stage RO Permeate Pump Flow Diagram 28...

Страница 29: ...from the date of purchase not the date of installation This warranty does not include filters or membranes Additional Terms amp Conditions Penguin Water will at its option either make repairs to corre...

Страница 30: ...ained in this warranty are the purchas er s exclusive remedies In no circumstan ces will PENGUIN WATER or the seller of the product be liable for more than and purchaser user s remedies shall not ex c...