Refer to Figure 7: Rack Rail Kit Parts above and follow these steps:
Step 1.
Attach the left and right rack mount rails (A) to the switch, by gently pushing the switch
chassis’ pins through the slider key holes, until locking occurs.
Step 2.
Secure the chassis in the rails by screwing 2 flat head Phillips screws (E) in the designated
points with a torque of 1.5±0.2 Nm. See the figure below.
Figure 9: Attaching the Rails to the Chassis
Step 3.
Attach the left and right rack mount brackets (B) to the switch, by gently pushing the switch
chassis’ pins through the slider key holes, until locking occurs. Secure the system in the brackets by
screwing the remaining 2 flat head Phillips screws (E) in the designated points with a torque of
1.5±0.2 Nm. See the figure below.