WaRnInG:
Only authorized service
technicians should attempt to service
this equipment. Use of other than
authorized technicians will void the
warranty.
WaRnInG:
Use a licensed electrician
for all wiring.
WaRnInG:
Failure to disinfect
the dental operating light between
patients could expose user/patient to
cross contamination and bio-burden/
bio-contamination.
WaRnInG:
To avoid risk of electric
shock, this equipment must be
connected
only
to supply mains with
protective earth.
WaRnInG:
No modification of this
equipment is allowed.
Electrical Specifications
All fuses are labeled at point of use.
Replace fuses only with type and rating
as indicated.
Volts Cycles Amps
115 VAC 60 HZ 1 A ~
230 VAC 50 HZ .6 A ~
IEC Medical Device Classification
Classification:
1
Type:
B
Operation Mode:
Continuous
Splash Protection: IPX0
WaRnInG:
The Helios light is not to
be used in rooms where an explosion
hazard exists.
WaRnInG:
Rotational stops are designed for a
maximum force limit of 25 lbs. If rotational stops
are broken, immediately take the equipment
out of use and have the equipment serviced.
Operation of damaged equipment could result in
injury to the operator and/or patient.
storage Conditions:
-4°F to 122°F/ -20°C to 50°C
10% to 90% Relative Humidity
As manufacturers of electro-medical products we can assume responsibility for safety-related performance of the
equipment only if maintenance, repair and modifications are carried out only by us or agencies we have authorized for
this purpose, and if components affecting safe operation of the unit that may be needed are replaced with original parts.
We suggest that you request a certificate showing the nature and extent of the work performed, from those who carry out
such work, and specify that the certificate show any changes in rated parameters or working ranges, as well as the date,
the name of the firm and a signature.
safeTy noTes
WaRnInG:
Failure to install set
screws & roll pin per Installation
Instructions could result in injury or
damage to equipment.
WaRnInG:
Power cords and their associated
parts cannot be substituted without increased
risk of electric shock or fire. We recommend the
use of Pelton & Crane replacement parts only!
Power cords must be installed by qualified
personnel. Make sure all service loops, strain
reliefs, and cord guards are in place and that
line, neutral and ground wires are secured.
WaRnInG:
This product must be disinfected
before use.