Can
adian Comfort Industries V04
23
PELPRO OWNERS MANUAL
Copyright 2004
www.pelprostoves.com
Dansons Group Inc.
L
IGHTING
Y
OUR
S
TOVE
Before lighting a fire check to ensure the Burn Grate is clean and adjusted and the Ash Tray is not full.
For safety reasons use extra caution when lighting a stove that is HOT!
Lighting stove manually (No Igniter)
In the NON-Thermostat Mode
Lighting stove with Auto-Ignitor
In the NON-Thermostat Mode
1. Push firmly on the
FEED RATE or START
touch pad.
-The
COMBUSTION FAN
(exhaust) will start and
operate at full speed for 60 seconds, then adjust
downward to match feed rate #1
-The
CONVECTION FAN
(heating) will start and the
LED will go solid on LOW setting
- The
AUGER CYCLE
LED
will go solid for 3 seconds,
indicating signal being sent to auger motor.
2. Place a small amount of a solid fuel fire starter, such
as those made from sawdust and wax or use wood
shavings, in the bottom of the burn grate.
Add a small handful of pellets to the starter material.
Add a small amount of fire starter over the pellets.
CAUTION: DO NOT USE ANY FLAMMABLE
LIQUIDS SUCH AS GASOLINE, GASOLINE-TYPE
LANTERN FUEL, KEROSENE, CHARCOAL
LIGHTER FLUID, OR SIMILAR LIQUIDS TO START
OR FRESHEN-UP THE FIRE! KEEP ALL SUCH
LIQUIDS WELL AWAY FROM THE HEATER
WHILE IT IS IN USE.
3. Light the fire starter and slowly close the
MAIN
DOOR
, leaving it about 1 inch open. When the
pellets are burning, close and latch the main door. If
the fire goes out when the main door is closed, add
more fire starter, re-light the fire and leave the main
door open an inch or so until the pellets start to burn,
then close and latch the main door.
4. Adjust the
FUEL RATE
and the
FAN
SPEED
to your
desired settings you require upon completion of
startup sequence.
1. Push firmly on the
FEED RATE or START
touch pad.
-The
COMBUSTION FAN
(exhaust) will start
and operate at full speed for 60 seconds, then
adjust downward to match feed rate #1
-The
CONVECTION FAN
(heating) will start
and the LED will go solid on LOW setting
- The
AUGER CYCLE
LED
will go solid for 3
seconds, indicating signal being sent to auger
motor.
-The
IGNITER
LED will light up solid and the
300 watt igniter will begin to operate.
2. On a primed
AUGER
system pellets will begin
to fall into the
BURN GRATE
, and the
AUTO
SELF IGNITER
will automatically ignite the
pellets in approx. 3 – 5 min.
Note: If stoves fails to light within 15 minutes,
shut off the stove, remove the pellets from the
burn grate and repeat step 2. If stove fails to
ignite a second time, disconnect and contact
your dealer
.
3. Adjust
the
FUEL RATE
and the
FAN
SPEED
to your desired settings you require upon
completion of startup sequence.
NOTE:
If the fire does not start, your stove will continue to feed pellets and the fans will run for approximately 15
minutes. The stove will then automatically shut off. If this happens, some unburned pellets will build up in the burn
grate. To restart the fire, clean the excess pellets out of the burn grate and follow the above "Lighting a Fire".
NOTE:
Some odors may be given off a new stove during the initial few hours of burning while the stove and the
paint are being cured. These odors are not harmful. However, ventilating the room until the odors disappear is
strongly recommended.
CAUTION:
Never use liquid or volatile fire starters to start a fire in your stove
! Do not install or operate your
stove in any room where any liquid or volatile fuels or any other highly combustible items are in the air or stored in
the room. These could cause a safety hazard.