Can
adian Comfort Industries V04
25
PELPRO OWNERS MANUAL
Copyright 2004
www.pelprostoves.com
Dansons Group Inc.
T
HE
C
ONTROLS
…
CONTINUED
TRIM POTS (Fine Tune Adjustments)
– Factory Settings
The
COMBUSTION
FAN (FAN),
HI (4) and
LO (1) FEED RATE trim pots
have been preset at the
factory, but may need to be adjusted onsite after your installation is complete. Due to different
installation setups, length and size of venting, and pellet fuel quality, the preset from the factory will
not always be correct. These settings will accommodate virtually all wood pellet fuels.
FUEL FEED
rates
at the Lowest (number 1) and highest (number 4) settings can be adjusted by
adjusting the fine tune trim pots located on the control panel. To
raise fuel feed
turn trim pot
counter clockwise
and to
lower
turn
clockwise
. To assist in knowing what the change is you
should note the amount of time the light on the AUGER CYCLE LED stays OFF.
(Note: The light
stays on when ever the fuel feed motor, AUGER CYCLE, is running).
Lengthening the time this
LED stays OFF lowers the fuel feed and shortening the off-time increases the fuel feed
.
COMBUSTION FAN SPEED (FAN)
In a few instances because of prevailing conditions pertinent to your specific installation, or even
different batches of pellet fuel, the
COMBUSTION FAN SPEED
may be adjusted to raise or lower
the amount of air moving through the grate for the cleanest burn. The FAN speed can be adjusted
by adjusting the
FAN
trim pot
COUNTER CLOCKWISE to INCREASE
the speed and
CLOCKWISE to DECREASE
the speed
of the combustion fan.
Note: If you attempt to adjust the Fuel Feed Trim Pots, use a small precision screwdriver.
The Trim Pots do not make a full rotation.
If using a metal screwdriver, be gentle as the plastic trim pot slot can be damaged or stripped.
FAN SPEED
(Convection or heating)
The
FAN SPEED
controls the speed of the room air fan. This fan blows room air through the heat
exchange tubes and back into the room. When the
FEED RATE
is set to a higher position, the
FAN
SPEED
should be set higher and visa versa. When the
FEED RATE
is set at [3 OR 4] set the
FAN
SPEED
to [MED]. If you forget, the room air fan's (L140) temperature limit snap switch automatically
sets the fan on high when your stove is producing heat faster than the fan is carrying it into the room.
This may occur when the heat control lever is set at [3 or 4] and the
FAN SPEED
is set to a very low
or off setting. After the fan runs at this automatic high setting a few minutes, it may cycle back to its
lower setting and may continue to cycle between [HIGH ] and your selected setting. The circulation
(room air) fan cycling
from high to low is a normal condition, as well as a safety feature of
your appliance.
AUGER CYCLE
The
AUGER CYCLE
LED indicates when a electrical signal is being sent to the auger motor. It is
NOT used to indicate the actual movement of the auger. When the signal is being sent the LED will
be solid for 3 seconds. When the LED is off no signal is being sent
.
S
HUTTING THE STOVE
OFF
Note:
DO NOT UNPLUG your stove if there is a fire going or if the stove is still active. This could result in smoke coming back
into the room. Remember the EXHAUST FAN is needed to force the exhaust out of the stove.
On the CCI “AcuTron” Board firmly touch the
OFF
touch pad. The
FUEL RATE
LED will turn off. The
AUGER CYCLE
LED will
turn off. The auger will stop feeding fuel to the fire and the
FAN
speed LED will flash indicating that the appliance is in the “Shut
Down” mode. The fire will go out and the fans will continue to run until your stove cools down at which time the fans will
automatically shut off and NO LED’s will remain ON.
HI
MED
LOW
FAN SPEED
OFF
FAN
SPEED
AUGER
CYCLE
FINE TUNE ADJUSTMENTS
1
4
FAN
Increase
Decrease