PV20a / PV30a pellet burner
page
16/ 41
DK9902A1 www.pelltech.eu
Notice!
All electrical connections of the burner must be made by a qualified professional.
Initial start up
2.5
Prior the initial start-up the burner make sure that:
•
The M6 nut that connects burner’s housing and burning chamber is securely tightened.
•
The neck of burning chamber fits correctly to burner’s housing.
•
The grate is placed correctly into burning chamber (Figure 14). The back edge of grate has to be
against the back wall of burning chamber and fixator stub is inside the chamber.
•
Igniter is not stuck behind buring chamber’s back wall and its end is on same level with end of its
holder tube and does not reach out form it. Igniter can not be in direct touch with pellets and flame.
•
Boiler thermostat is installed correctly and functioning properly.
•
The boiler thermostat is turned to lowest temperature.
•
The external auger is connected to the burner according to Figure 11.
•
The smoke duct is connected to the chimney, the dampers for smoke gases are open and
sufficient draught exists. When the burner is operating, the negative pressure inside the
boiler must stay between 4 and 6 Pa.
Boiler’s air hatches are closed and all air goes thru the boiler.
•
Electrical plugs of external auger and boiler on burner’s right side are pushed fully into outlets. They
should lock with plastic stub clip.
To turn on the burner
, switch on boiler’s main power switch. If STOPPED is displayed in controllers
screen press OK button on user interface and toggle down with the „down“ (↓) key to BURNER menu.
Then, press OK and „down“ (↓) key to toggle from OFF to ON then press OK to approve the change.
Press ESC to return to the STATUS display. WAITING is displayed. Now turn the boiler’s thermostat to
desired temperature. The burner will now go into TESTING mode then LOADING mode. If this is the first
5- wire
connection
Tt – Boiler thermostat
4- wire
connection
Figure 12 Thermostat connections
Figure 13 Socket connections
Tt