PV20a / PV30a pellet burner
page
17/ 41
DK9902A1 www.pelltech.eu
run, the external auger may need up to 20 minutes to load. After the pellets are loaded the burner will
go into IGNITION mode then PRE-BURN mode then finally BURNING mode where it will remain until it
reaches the temperature by the thermostat. When it reaches this temperature the burner will go into
END BURN mode and finally END BLOW until all the pellets coals have extinguished. At that point the
burner will be in WAITING mode until the boiler calls for more heat which starts the whole process over
again.
To stop the burning
, turn the boiler’s thermostat down or turn the burner OFF from the BURNER’s
menu or keep OK button down for 5 seconds.
Caution!
Never turn off a working burner from the main power switch of the boiler. Do not leave the
burner unattended when it has been necessary to turn off the burner’s power while in operation.
3
Optional components
GSM modem
3.1
GSM modem enables to send burner error SMS messages with 7 last statuses or error message up to 5
phone numbers. If there are more error messages, then less status info rows will be sent by SMS.
Stopper of grate is inside of burning chamber
inside the camber
1
Grate has to be against the back wall
UART
2
3
GND
Tx
Rx
+5V
UART
X2-8
White (+)
X2-4
Brown (-)
Figure 14 Grate's correct placement
Figure 15 Connecting the modem
Following 3 products are needed to set up
modem:
1 – Modem signal converter cable EP0005 to be
connected between modem and UART socket
2 – Modem EP0007
3 - Modem power cable EP0001