SPECIAL FEATURES
SENSOR TEST MODE
Sensor test mode may be used to determine if an
Insynctive
™
SENSOR is operating properly.
• To enter SENSOR test mode, press and release the Test
button on BRIDGE. BRIDGE will beep and light will turn
solid orange.
• Operate any SENSOR (open or close SENSOR, lock
or unlock deadbolt, etc.) to begin the test. If SENSOR
is operating properly and signal strength is good,
BRIDGE will beep three times and light will turn green.
• If signal strength is poor, BRIDGE will issue a
long tone and light will turn red. If this occurs,
see troubleshooting information on page 14.
• If there is no response from BRIDGE, try operating
SENSOR again. If there is still no response, see
troubleshooting information on page 14.
Z-WAVE TEST MODE
Z-Wave test mode can be used to verify that BRIDGE
is able to communicate with the Z-Wave home automation
system.
• Press and hold the Test button on BRIDGE, and release
when the light turns blue.
• BRIDGE will issue two long tones and the light will be
solid blue as it attempts to communicate with the Z-Wave
home automation system.
• If communication is successful, BRIDGE will beep three
times and light will turn green.
• If communication is unsuccessful, BRIDGE will issue
a long tone and light will turn red. If this occurs, see
troubleshooting information on page 14.
LIGHT
SYNC
BUTTON
TEST
BUTTON
LIGHT
SYNC
BUTTON
TEST
BUTTON