background image

YOU WILL NEED TO SUPPLY:

TOOLS REQUIRED:

Ř

Composite or Impervious shims/spacers  
(12 to 20)

Ř

High quality exterior grade polyurethane or 
silicone sealant (3 to 4 tubes per door)

Ř

Great Stuff™ Window and Door Insulating 
Foam Sealant by the Dow Chemical Company 
or equivalent low pressure polyurethane 
window and door foam - DO NOT use high 
pressure or latex foams.

Ř

Wood blocking, 3/4" x 4" x 96" (2 or 3 pieces)

Ř

Screws (#10 x 3-1/2")

Ř

Pella® SmartFlash™ foil backed butyl flashing 
tape or equivalent. 

Ř

Sill pan

Ř

Tape measure

Ř

Level

Ř

Sealant gun

Ř

Square

Ř

Hammer

Ř

Screwdriver

Ř

Utility knife

Ř

Wide jaw pliers

Ř

Reciprocating saw

Ř

1/8" and 1/4" drill bit

Ř

Drill

4&"-"/5

4&"-"/5

Installation will require two or 
more persons for safety reasons.

1A

A.  

Remove the vent panel from the existing door frame. 

Check the dimensions of the 

existing door and the new door to make sure the new door will fit correctly. The opening 
must be 1/2" larger than the new door frame in both width and height. Measurements 
should be taken as follows:  
Width - measure the inside dimension of existing jambs.  
Height - measure from the subfloor or cement slab to the lowest point of the existing head. 
Confirm the flange will overlap the stucco by 1/2".

1

 

BEFORE YOU START

Содержание 81CM0100

Страница 1: ...d additional care Determining the appropriate installation method is the responsibility of you your architect or construction professional If you have questions please contact your local Pella retaile...

Страница 2: ...asure Level Sealant gun Square Hammer Screwdriver Utility knife Wide jaw pliers Reciprocating saw 1 8 and 1 4 drill bit Drill 4 5 4 5 Installation will require two or more persons for safety reasons 1...

Страница 3: ...ealant and other debris from the door opening 2B NOTE 2B 2B 2A F If the weep holes of the existing sill have been cut away drill new weep holes in the existing door jambs Be sure to drill weep holes i...

Страница 4: ...ound the end of the pan Dry t the sill pan and the door into the opening J If there is a step down at the exterior of the door opening cut the sill nosing to the rough opening width plus two times the...

Страница 5: ...2L M If using sill nosing with a step down Install the sill pan and sill nosing into the opening Press down to seal them into the opening DO NOT overlap N Apply sealant at nosing ends continuing from...

Страница 6: ...B Remove the shipping spacers Carefully slide the movable panel halfway open and remove the spacers from both the top and bottom of the movable panel C Remove the venting panel by lifting it off of th...

Страница 7: ...o the opening and that the door anges will overlap the stucco or existing aluminum door frame by a minimum of 1 2 on all sides REMOVE THE DOOR FROM THE OPENING D Place three 3 8 beads of sealant Place...

Страница 8: ...Note If the dimensions are not equal check to make sure the ns are folded out to 90 at all points K Secure the frame Insert a 1 wide shim behind the pilot hole at the lock strike s Insert a 8 x 2 1 2...

Страница 9: ...corrosion resistant wood screws through the holes in the threshold in to the oor Note For concrete oors use masonry screws a minimum size of 3 16 x 3 1 2 4N L Apply sealant and insert a 8 x 2 1 2 pan...

Страница 10: ...he exterior of the building tilt the top of the panel toward the door frame and insert the top of the door panel into the top track Move the bottom of the panel toward the door frame until it is verti...

Страница 11: ...ion of the foam and will minimize squeeze out Apply sealant across the interior surface of shims to create a continuous seal For doors with jamb extensions installed ensure the foam is placed between...

Страница 12: ...urface Clad Exterior Frame The exterior frame is protected by aluminum cladding with our tough EnduraClad baked an factory nish that needs no painting Clean this surface with mild soap and water DO NO...

Страница 13: ...ruction must anticipate some water in ltration it is important that the wall system be designed and constructed to properly manage moisture Pella Corporation is not responsible for claims or damages c...