© 2019 Enviro Water Solutions, Inc.
3060 Performance Circle, Suite 2, DeLand, FL 32724
PelicanWater.com
(877) 842-1635
Rev A
Page 1
3
Pelican WF5/WF9 Iron/Manganese Filter
Sediment Filter Cover
Installation
Sediment Filter Assembly
Figure 5
1. Unscrew the cover from the Blue Filter Housing.
2. Remove the plastic covering from the Sediment Filter.
3. Place the Sediment Filter onto the Stand Pipe in the Blue Filter Housing and set aside.
Sediment Filter Installation
Figure 6
1. Shut off the water.
2. Attach the Filter Cover to the Mounting Bracket using the supplied Bolt Head Screws and
Washers. Make sure to properly orientate the IN and OUT to match your flow pattern.
3. Attach the Mounting Bracket to the wall using the supplied Phillips Head Screws.
4. Hand tighten the Blue Filter Housing and then using the supplied Filter Wrench lightly snug
the housing making sure not to over-tighten. (counter clockwise).
5. Determine the size of your inlet water supply line. Reducers may be needed to fit the 1”
Sediment Filter System.
Notice:
The Sediment Filter Housing comes with a 1” threaded female inlet/outlet and will require additional
fittings to adapt to your plumbing. A shut-off valve is recommended prior to the Sediment Filter System.
Stand Pipe
Blue Filter Housing
O-Ring x2
Sediment Filter
Mounting
Bracket
Inlet Water
Supply
Blue Filter Housing
Top View