© 2019 Enviro Water Solutions, Inc.
3060 Performance Circle, Suite 2, DeLand, FL 32724
PelicanWater.com
(877) 842-1635
Rev A
Page 1
9
Pelican WF5/WF9 Iron/Manganese Filter
3. Remove the white cap from the top of the Whole House Iron & Manganese tank.
4. Using regular unscented household bleach pour ½ gallon of bleach into the Iron and Manganese
tank. Add enough water to cover the media. Note: Soak for a minimum of 3 hours, the more the
better.
5. Screw the Electronic Head onto the tank hand-tight.
6. Install the fittings onto the inlet and outlet, following the arrows on the Bypass Valve andhead.
7. Connect the incoming water supply to the fitting on the inlet side of the Bypass Valve.
8.
Connect the outgoing water supply to the outlet side of the Bypass Valve.
Leave tank in bypass mode.
9. Firmly press one end of the discharge Tubing Drain Line onto the barbed nose and secure the
other end of the line to a drain.
IMPORTANT!
•
Ensure the PVC Tubing Backwash Drain
Line is not submerged and is free of kinks.
•
Maximum vertical rise of the backwash line
is 6 feet.
•
If incorporating two or more backwashing
systems make sure to keep the drain lines
separate.