Pelican WF5/WF9 Iron/Manganese Filter 

© 2019 Enviro Water Solutions, Inc. 

3060 Performance Circle, Suite 2, DeLand, FL 32724 

PelicanWater.com 

(877) 842-1635

Product Operation and Specifications 

Specification Description 

WF5 

WF9 

Max Flow Rate 

10 GPM 

15 GPM 

Minimum Working Pressure 

25 PSI 

Maximum Working Pressure 

80 PSI 

Maximum Vacuum 

5 inch/127 mm Hg 

Operating Temperatures 

36°F – 100°F 

pH Range 

7 - 11 

Important Information 

Read these instructions carefully and determine the location of all system components before

beginning installation.

Check all applicable plumbing, building, and electrical codes for installation compliance.

Install the system on the main water supply.

Systems that contain electronic components cannot be installed outside in uncovered areas.

Water Conditions for Operation 

The water should be free of hydrogen sulfide, a dissolved gas with a characteristic smell of rotten

eggs. If present, it can coat the catalytic surface of the media and interfere with the process. The gas

should be removed through adequate pre-treatment.

The water should be free of hydrocarbons, oils, and lubricants. If present, they can coat the catalytic

surface of the media and interfere with the process. Remove through adequatepre-treatment.

 

WARNING:

If this or any other system is installed in a metal (conductive) plumbing system, i.e. copper or 

galvanized metal, the plastic components of the system will interrupt the continuity of the 

plumbing system. As a result any errant electricity from improperly grounded appliances 

downstream or potential galvanic activity in the plumbing system can no longer ground 

through contiguous metal plumbing. Some homes may have been built in accordance with 

building codes, which actually encouraged the grounding of electrical appliances through the 

plumbing system. Consequently, the installation of a bypass consisting of the same material 

as the existing plumbing, or a grounded "jumper wire" bridging the equipment and re- 

establishing the contiguous conductive nature of the plumbing system must be installed prior 

to your systems use. 

CAUTION: 

When adding a filtration/softening system to homes/buildings supplied by well water, the system should be 

installed following the pressure tank. 

DO NOT USE this system for pneumatic or hydro pneumatic 

applications. If you are using a booster pump, then install this system following the booster 

pump. 

If you have questions, please call customer service. 

Содержание WF11

Страница 1: ...Owner s Manual Pelican WF5 WF9 Iron Manganese Filter...

Страница 2: ...nd fitness for a particular purpose Pelican Water Systems shall not be liable for technical or editorial errors or omissions contained herein or for incidental or consequential damages in connection w...

Страница 3: ...nstallation 12 Sediment Filter Assembly 12 Sediment Filter Installation 12 Chemical Injector Pump and SolutionTank Installation 13 Chemical Injector Pump Installation 14 Solution Tank Installation 14...

Страница 4: ...If present they can coat thecatalytic surface of the media and interfere with the process Remove through adequatepre treatment WARNING If this or any other system is installed in a metal conductive pl...

Страница 5: ...sing Mounting Bracket Phillips Head Screws 4 Bolt Head Screws 4 and Washers 4 1 Sediment Filter 5 Micron Poly Spun Sediment Filter 1 EN U SE T Electronic Head 1 PVC Tubing Drain Line 50 ft 1 Chlorine...

Страница 6: ...Performance Circle Suite 2 DeLand FL 32724 PelicanWater com 877 842 1635 Part Description Qty Pelican Whole House Water Filter 1 Part Description Qty Pelican Whole House Iron Manganese Filter 1 Note...

Страница 7: ...Water Meter Chlorine Injector Plumbing T not included From Well To Home Discharge Line Purge Line Solution Intake Model No Max Flow Rate 10 15 Max Temp 120 Max Pressure 80 DWGNo 1 Scale WF 5 7 Non Re...

Страница 8: ...Well Pressure Tank Sediment Filter Water Meter From Well To Home Discharge Line Purge Line Solution Intake Model No Max Flow Rate 15 Max Temp 120 Max Pressure 80 DWG No 1 Scale WF 7 11 With Retention...

Страница 9: ...Pelican Whole House Water Filter or Salt Free Water Softener Conditioner with the unthreaded ends orientated towards the tank and hand tighten the Quick Connect Nuts Whole House Iron Manganese Filter...

Страница 10: ...difficult to turn by hand until the seals become saturated Use the supplied Bypass Allen Wrench to turn the knobs if necessary Note The Red Arrows on the Whole House Carbon Filter Bypass may be point...

Страница 11: ...ypass Valve during this process Be sure you perform this series of steps in a location suitable for water flow Figure 3 1 Attach a garden hose to the Hose Bib Assembly 2 Connect the Hose Bib Assembly...

Страница 12: ...n the hose spigot 3 Run water through the inlet side of the Bypass Valve for 30 minutes to expel the carbonfines 4 Turn off the water 5 Remove the Hose Bib Assembly from the inlet side and attach it t...

Страница 13: ...s and Washers Make sure to properly orientate the IN and OUT to match your flow pattern 3 Attach the Mounting Bracket to the wall using the supplied Phillips Head Screws 4 Hand tighten the Blue Filter...

Страница 14: ...Pulse LED Red 3 Level alarm LED Yellow Optional Accessary 4 Adjustment knob of injections min number 0 100 max flow Volumetirc Proportional Mode 1 1 1 injection per 1 signal as indicated by F Mode Vo...

Страница 15: ...Pump and Solution Tank Installation Fig 8 Solution Tank Well Pressure Tank Sediment Filter Water Meter Chlorine Injector Plumbing T not included From Well To Home Discharge Line Purge Line Solution In...

Страница 16: ...the hole drilled prior 8 Pull tube up until foot filter is suspended about 4 off the bottom of the tank Cut tubing squarely leaving about 6 exposed 9 Remove the suction valve nut and insert the tubing...

Страница 17: ...f thread tape with tread sealant If you wish to use a PVC CPVC slip glued fitting cut threads off of pipe and use a coupler to adapt to a slip glued fitting 2 Using reducer bushings adapt fitting to s...

Страница 18: ...on the ground until the tank stands vertical The bottom of the tank is round and the boot allows the tank to stand upright 2 Determine the size and material of your incoming water supply line from th...

Страница 19: ...tank hand tight 6 Install the fittings onto the inlet and outlet following the arrows on the Bypass Valve andhead 7 Connect the incoming water supply to the fitting on the inlet side of the BypassValv...

Страница 20: ...and upright 2 Determine the size and material of your incoming water supply line from the Whole House Iron Manganese Filter and choose the appropriate plumbing required to adapt to the 1 Male NPT Asse...

Страница 21: ...Filter 5 Connect the outgoing water supply to the outlet side of the Bypass Valve CAUTION Avoid high flow rates such as bathtub utility sinks hose bibs multi headed showers body sprayers or anything t...

Страница 22: ...urn to the main menu IMPORTANT You will need to manually regenerate Regen Now your system prior to use Do not run water in the home until this step is done To do so follow the programming below You wi...

Страница 23: ...ts and spigots off 2 Press Pressure Release Button on top of Injection Pump 3 Check for leaks 4 Peel off the protective plastic wrap from the stainless steel tank jackets 5 Add the Pelican logo sticke...

Страница 24: ...pulse for every gallon of water run Watch water level in tube to make sure it is lifting 7 Let the water run for 5 minutes or measure 30 gallons of water on water meter 8 After 5 minutes or 30 gallons...

Страница 25: ...O Ring down into the groove with twofingers Note This step is important to ensure the proper filter seal Make sure the O Ring is seatedlevel in the groove If the O Ring appears damaged stretched or cr...

Страница 26: ...anganese tank needs to be backwashed Incorrect day override selected on electronic head Decrease the day override one day and start a manual backwash Observe results after one day of use Electronic he...

Страница 27: ...icitly excluded with respect to defects or damages due to neglect misuse alterations accident misapplication physical damage or damaged caused by fire acts of God or freezing These warranties apply on...

Страница 28: ...Warranty Registration Form Send To Pelican Water Systems 3060 Performance Circle Suite 2 DeLand FL 32724 Phone 1 877 842 1635 Plumber s Information optional We like to recommend good plumbers through...

Страница 29: ...ns Pelican NaturSoft NS3 NS6 WQA Gold Seal tested and certified under NSF ANSI 61 for materialsafetyandtestedaccording to NSF ANSI 42 forstructural integrityonly The Pelican Natursoft is DVGW DW 9191...

Отзывы: