22
installation dimensions
Factory setting:
2 phase and 2 zero connection (2 2N a.c. 230V/50 Hz):
The voltage between the phases and the zeros is 230V a.c.
Fit a connecting bridge between connecting points1 and 2.
The group must have fuses of at least 16 A (2x) The core
diameter of the connecting cable must be at least 2.5 mm
2
.
These connections may only be used if the appliance has
been adjusted for a 2-phase connection, see page 24.
Common connection:
3 phases with 1 zero connection (3 1N a.c. 400V/50 Hz):
The voltage between the phases and the zero is 230V a.c.
The voltage between the two phases is 400V. Fit a
connecting bridge between connecting points 4 and 5. The
groups must have fuses of at least 16 A (3x). The core
diameter of the connecting cable must be at least 2.5 mm
2
.
Special connections:
Single phase connection (1 1N a.c. 230V/50 Hz):
The voltage between the phase and the zero is 230V a.c.
Fit a connecting bridge between connecting points 2 and 2,
2 and 3, and 4 and 5. The group must have a fuse of at least
40 A. The core diameter of the connecting should be at least
6 mm
2
.
3 phase, no zero connection (3 a.c. 230V/50 Hz):
The voltage between the phases is 230V a.c. Fit connecting
bridges between connecting points 1 and 2, and 4 and 5.
The group must have fuses of at least 16 A (3x). The core
diameter of the connecting cable must be at least 2.5 mm
2
.
These connections may only be used if the appliance has
been adjusted for a 2-phase connection, see page 24.