![PEKO ETS-1700E Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/peko/ets-1700e/ets-1700e_installation-and-operating-manual_1522294008.webp)
Installa on
and
Opera ng
Manual
Page
8
INSTALLATION
ELECTRICAL CONNECTION
The cabinet is supplied ready for connection to the power supply with a UK style 3-pin plug complete with
a 10 A fuse.
Power supply rated at 220 – 240V single-phase 50 Hz.
The power cable is approx. 1.9 m in length.
The plug (and socket outlet) should be in an accessible position for ease of removal. An alternative
arrangement could be a socket positioned above the cabinet with a separate fused switch at worktop
height.
Check that the supply current matches that stated on the identification plate and that the mains lead is
correctly earthed according to the standards in force. We recommend that the power supply is fitted with a
residual current device (RCD).
The manufacturer cannot be held liable if the electrical connections are not carried out as prescribed in
this manual.
NOTE.
If the power cable
is
damaged in any way, it must be
replaced immediately.
Replacements are available from
your main supplier or dealer.
WARNING!
If the plug supplied is not suitable for the
socket outlet, or if the appliance is to be connected to fixed
wiring, it should be cut from the supply cord and disposed
of immediately. If the severed plug is introduced into a
live socket outlet there is a risk of electric shock.
NOTE.
Should the plug need to be replaced for any reason, the wires in the mains lead are
coloured in accordance with the following code:
Green and Yellow = Earth
Blue = Neutral
Brown = Live
The wire coloured green and yellow must be connected to the terminal marked with the letter ‘E’,
the earth symbol , or coloured green and yellow. The wire coloured blue must be connected to
the terminal marked ’N’ or coloured black. The wire coloured brown must be connected to the
terminal marked ‘L’ or coloured red. If the fuse incorporated in the plug needs to changed, then it
should be replaced with a fuse approved by ASTA to BS1362, rated at 10 A.
WARNING!
This appliance must be earthed. If in any doubt,
consult a competent person.