![PEKO ETS-1700E Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/peko/ets-1700e/ets-1700e_installation-and-operating-manual_1522294013.webp)
Installa on
and
Opera ng
Manual
Page
13
ADJUSTING THE DRYING PROGRAMMES
INTRODUCTION
The drying cabinet is equipped with two automatic programmes,
40
°
and
60
°
. The automatic
programmes end when the washing is dry. To determine when the washing is dry, a measured value is
taken from the exhaust duct and compared with a factory-set parameter;
parameter
P4 for the 40
°
programme
parameter
P8 for the 60
°
programme
.
It is primarily these two parameters that are adjusted to optimise the drying process of the automatic
programmes.
If you find the washing is under-dried,
increase the parameter value
for the relevant programme
If you find the washing is over-dried,
decrease the parameter value
for the relevant programme
Optimisation of the drying process must always take place in small steps. Start by adjusting the
parameter concerned by 1 - 2 units up or down, then check the result after the next drying process. If
required, make further adjustments in the same way.
PROCEDURE
The drying cabinet’s parameter list is accessed through the control panel. The parameter list appears one
line at a time on the control panel display.
1. Make sure that the main
ON/OFF
switch on the cabinet is
OFF
(the green indicator is also off).
2. Hold down the
+
and
-
buttons and press the main
ON/OFF
switch on the cabinet (the green light
will appear). The display lights up and shows the parameter
P1
and its factory-set value.
3. Step through to the required parameter by pressing the
MAN
button repeatedly.
If you go too far, simply continue selecting forward until the display shows the correct parameter.
4. When the display shows the correct parameter, e.g.
P8
,
press the
+
or
-
buttons to increase or
decrease the value.
5. To save the set value and return to the operating mode, press the
START/STOP
button. The display
now shows the last used programme.
NOTE.
If you wish to restore the parameter list to the factory setting:
1.
Go to the parameter display mode as describe in steps 1 - 2 above.
2.
Hold down the
40
°
button
and press the
START/STOP
button. The parameter list
reappears and the display shows
P1
and its factory-set value.
3.
To save the factory setting and return to operating mode, press the
START/STOP
button.
CARE
The inside and outside of the cabinet should be
cleaned with a mild soap solution and a damp
cloth.
Dust will collect on the top of the cabinet,
especially around the air intake. This can cause
operational faults within the cabinet, as well as
pose a fire hazard.
To avoid any potential problems, the top of the
cabinet should be vacuum cleaned at least once
a year, or more frequently depending on the
location of the cabinet and its application.
CLEANING
NOTE.
High-pressure cleaning should
not
be used.