GB-22
FunCTIOnS
Function
Description
Timer
The JRM’s timers can be used to move the motors UP and DOWN at specific times. Setting the timer to 00:00 deactivates
it. The timers are programmed via the JRM module’s keyboard and display (see page 7). Auto mode must be switched ON
if the device is to function properly!
Twilight sensor
In twilight conditions, the motors run DOWN when the twilight sensor sends an ON signal. When an OFF signal is sent, the mo
-
tors run UP. When the twilight sensor transmits an ON signal and the wind/rain sensor is active, the ON signal is retrieved after
the OFF signal from the wind/rain sensor.
Auto mode must be switched On
if the device is to function properly!
Sun sensor
All assigned motors move
DOWn
(with 1s slat adjustment for blinds) when the sensor transmits an
On signal
. The motors
move
uP
when the sun sensor transmits an
OFF signal
. The sensor assignment and lowering time can be set for each mo
-
tor (see Page 14). When the sun sensor transmits an ON signal and the wind/rain sensor is active, the ON signal is retrieved
after the OFF signal from the wind/rain sensor.
Auto mode must be switched On
if the device is to function properly!
Note:
When the motor is controlled at a pushbutton or with another sensor, the sun sensor is ignored until the motor has
moved UP to the top (e.g. at the central UP button)!
Wind-/ Rain sensor
All assigned motors move UP and are locked when the sensor transmits an
On signal
. This is particularly recommended
for awnings! Manual pushbutton operation is then not possible. All motors are disengaged again when the OFF signal is
transmitted.
The sensor assignment can be set for each motor (see Page 14)
.