GB-18
OPERATIOn
BROADCAST
Note:
A system with more than one compact module can be controlled with the one common set of sensors. The modules must be interlinked via
the compact bus (see page 24). The module with the connected sensors must be configured as the first module in the bus and as the master. All
of the following modules are configured as slaves. The sensor data are transmitted via the compact bus every two minutes and every time the
sensor value changes. A mode change reboots the module!
Setting:
Mo d e :
OF
F
M o d e
Selection:
Finish:
Prog
12 Broadcast
D e v i c e m e n u
Factory setting
Mode
Sensors
Mode: Off
Off, Master, Slave
external (Ext.): External Sensor data
Internal (Int.): Internal Sensors
Enter
Prog
Prog
Enter
Mo d e :
Slave
A uto m a ti c :
E x t
.
T w i l i g h t:
Ext.
S un 1:
Ext.
S un 2:
Ext.
S un 3:
Ext.
W i nd :
Ext.
M o d e
Setting:
Selection: Enter
External sensor data (compact bus)
• Automatic
• Wind / Rain
• Twilight
• Sun 1
• Sun 2
• Sun 3
Internal Sensors
Module inputs I30-I35