GB-29
G B
7
Question
:
How high a load can the 24V sensor connection withstand?
Answer
:
Max. 100 mA.
8
Question
:
Can direct current motors be used as well?
Answer
:
No, only alternating current motors (230V~/50Hz max. 1A)
.
9
Question
:
Can motors be connected in parallel?
Answer
:
No, only one motor (230V~/50Hz max. 1A) per output.
10
Question
:
Is the Compact system compatible with the PHC system?
Answer
:
No!
11
Question
:
Can several buttons be connected to one input in parallel?
Answer
:
Yes, several buttons can be connected in parallel.
12
Question
:
How high a load can the outputs withstand?
Answer
:
At 230 V~ /50 Hz max. 1A per output.
13
Question
:
Why is the label on the first three outputs (motors) red on the JRM?
Answer
:
The red label serves to specially identify the outputs. Motors M0, M1, M2 can be connected together, or M0 and M1 can be connected
separately from M2 (e.g. for RCD protective switch). A phase leg (e.g. L1) must be connected to the L0 terminals to supply the motors with
power (230V~/50Hz).
Caution!
The L0 terminals require the same potential!