GB-27
G B
nEW SySTEM OR ExISTInG SySTEM
• Check the automatic circuit breakers and supply voltages.
• Check the connection cables for the inputs (buttons, sensors).
• Check the compact bus port.
•
Auto mode has not been switched ON.
• Observe the prioritisation of the input functions! For example, if a local DOWN button is used to move a blind, the signals transmitted by the sun sensor
will be ignored (locked)! An input function, e.g. local UP, must first be activated to unlock the system!
EMC PROBLEMS
• Use separate connections for the control and motor lines!
• Do not lay the wiring behind the JRM!
•
Relocate the JRM.
MOTOR DOES nOT MOvE OR MOvES In THE WROnG DIRECTIOn
• Check the connecting cables and polarity of the motors.
• Check the connecting cables and polarity of the button lines.
• Check the programmed timers and sensor/group assignment.
• The cable for supplying power to motors M1 and M2 or M2 has not been connected (separate supply)!
TROuBLESHOOTInG & REMEDIES (AuTHORISED ELECTRICIAn)
ELEKTROPLANET AG
IHR P
AR
TNER FÜR DIE ELEKTROBRANCHE
INDUSTRIESTRASSE 2
CH - 8
33
5
HITTNAU
+41 (0) 44 950 10 10
+41 (0) 44 950 10 44
WWW
.ELEKTROPLANET
.CH
INFO@ELEKTROPLANET
.CH