PASSWORD FUNCTION
The password function activates by setting a value different from 0 for parameter PA. See
parameter P1 for the different protection levels.
Protection is enabled automatically after approx. 2 minutes of inactivity on the keyboard.
Numbers 000 appear on the display.
By keeping SET pressed, the first digit flashes for amendment using up/down arrow.
Release SET and press SET again: the second amendable digit flashes.
Release SET and press SET again: the third amendable digit flashes.
The operation is cyclical and therefore by pressing SET again, the first digit flashes again,
and so-on.
If the password is forgotten use the universal number 100.
AUTOMATIC PROGRAMS
An automatic program is a work cycle made of a maximum of 7 phases in which it is
possible to automatically amend the temperature and the humidity set point when passing
from one phase to the following one.
In each phase it is possible to choose whether to enable or not the movements (managed
with parameters Pr and dr) and manage a different speed for the fans.
It is possible to set up to 5 programmes (identified with Pr1, Pr2, Pr3, Pr4, Pr5) each of
which has a different setting according to the table of paragraph 5.10.
For each program, the first phase is defined dripping or phase 0; 5 process phases follow.
The last phase is the seasoning / preserving phase with unlimited duration in time.
5.21
5.22
CHAP. 5 - Parameters programming