![Pego 100N MASTER Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/pego/100n-master/100n-master_use-and-maintenance-manual_1521986022.webp)
PLUS
300 EXPERT
U THR
Pag. 22
USE AND MAINTENANCE MANUAL
Rev. 01-18
rn3
Phase 3 refreshment
0 = NO
1 = YES
0
v3
Phase 3 evaporator fans speed. Amends
the value of 2nd level variable (F8)
0 = High speed
1 = Low speed
(only if rin = 1)
0
t3
Phase 3 duration
0:00...99:30
(30 min steps)
0:00
St4
Phase 4 temperature setpoint
-45 ÷ +45°C
0
SU4
Phase 4 humidity setpoint
0...99 rH%
0 = Disabled
60%
rn4
Phase 4 refreshment
0 = NO
1 = YES
0
v4
Phase 4 evaporator fans speed. Amends
the value of 2nd level variable (F8)
0 = High speed
1 = Low speed
(only if rin = 1)
0
t4
Phase 4 duration
0:00...99:30
(30 min steps)
0:00
St5
Phase 5 temperature setpoint
-45 ÷ +45°C
0
SU5
Phase 5 humidity setpoint
0...99 rH%
0 = Disabled
60%
rn5
Phase 5 refreshment
0 = NO
1 = YES
0
v5
Phase 5 evaporator fans speed. Amends
the value of 2nd level variable (F8)
0 = High speed
1 = Low speed
(only if rin = 1)
0
t5
Phase 5 duration
0:00...99:30
(30 min steps)
0:00
St
Seasoning/preservation temperature
setpoint
-45 ÷ +45°C
0
SU
Seasoning/preservation humidity setpoint
0...99 rH%
0 = Disabled
60%
tSC
Seasoning/preservation end timeout
0 ÷ 240 days
0
vSC
Seasoning/preservation evaporator fans
speed. Amends the value of 2nd level
variable (F8)
0 = High speed
1 = Low speed
(only if rin = 1)
0
GERMINATION DAY/NIGHT CYCLE
To access the day/night cycle parameters for germination lights it is necessary to:
1.
Check that parameter Cg = 1 .
2.
Keep keys
(
)
DOWN and
LIGHT pressed for a few seconds.
3.
Using key
(
)
or key
(
)
select the parameter
to be amended.
4.
Amend the setting by keeping the SET key pressed and by pressing one of the keys
(
)
or
(
)
.
CHAP. 5 - Parameters programming
5.12