Part I: Install the wallPlate
1. Position the wallplate on the wall with the directional arrow pointing up (see Fig. 3) and
terminal blocks facing outward.
2. Pull equipment wires through the wallplate wiring passage (see Fig. 3).
3. Use a level to determine the best horizontal wallplate mounting position.
4. Mark positions of the screw holes (two at minimum) with a pencil and remove wallplate.
5. Drill holes at pencil-marked locations (3/16” for drywall, 7/32” for plaster).
6. Insert the wall anchors in the holes, tapping them into place.
7. Mount the wallplate onto the wall and insert screws through mounting holes. Assure
that all loose wires come through the center opening of the backplate (see Fig. 3).
8. Cap off any unused wires and terminate properly according to local building codes.
Part II: attach wIres to thermostat wallPlate
1. Select the terminal designations that correspond to the system type (see Table 1).
Conventional Terminal Letters
Heat Pump Terminal Letters
c
Unswitched side, 24 VAC c
Unswitched side, 24 VAC
w1
Stage 1 Heat
B/o
Reversing Valve
w2
Stage 2 Heat
aUX
Auxiliary (Stage 3 Heat)
G
Fan
G
Fan
a
a
e
e
Y1
Stage 1 Cool
Y1
Compressor Stage 1, Heat /Cool 1
Y2
Stage 2 Cool (or
Dehumidify)
Y2
Compressor Stage 2, Heat /Cool 2
(or Dehumidify)
rh
Power for heating,
switched side, 24 VAC
rh
Power for heating,
switched side, 24 VAC
rc
Power for cooling,
switched side, 24 VAC
rc
Power for cooling,
switched side, 24 VAC
sc
Sensor Common
sc
Sensor Common
s1
Indoor Remote Sensor
s1
Indoor Remote Sensor
s2
Occupancy Setback Input s2
Occupancy Setback Input
System Type 1: 1H/1C Conventional
System Type 2: 1H/1C Heat Pump
TERM
Function
TERM
Function
C
Common
C
Common
W1
Heat
B/O
Reversing Valve
W2
AUX
G
Fan
G
Fan
A
A
E
E
Y1
Cool
Y1
Compressor
Y2
Y2
RH
Power for Heating
RH
Power for Heating
RC
Power for Cooling
RC
Power for Cooling
System Type 3: Heat only (without fan)
System Type 4: Heat only with fan
TERM
Function
TERM
Function
C
Common
C
Common
W1
Heat
W1
Heat
W2
W2
G
G
Fan
A
A
E
E
Y1
Y1
Y2
Y2
RH
Power for Heating
RH
Power for Heating
RC
RC
System Type 5: Cool only
System Type 6: 2H/1C Heat Pump (Aux.)
TERM
Function
TERM
Function
C
Common
C
Common
W1
B/O
Reversing Valve
W2
AUX
Auxiliary Heat
G
Fan
G
Fan
A
A
E
E
Y1
Cool
Y1
Compressor
Y2
Y2
RH
Power for Heating
RH
Power for Heating
RC
Power for Cooling
RC
Power for Cooling
System Type 7: 2H/2C Conventional
System Type 8: 2H/1C Conventional
TERM
Function
TERM
Function
C
Common
C
Common
W1
Heat 1
W1
Heat 1
W2
Heat 2
W2
Heat 2
G
Fan
G
Fan
A
A
E
E
Y1
Cool 1
Y1
Cool
Y2
Cool 2
Y2
RH
Power for Heating
RH
Power for Heating
RC
Power for Cooling
RC
Power for Cooling
all electrIcal loaDs
mUst Be connecteD to
termInal c (24 vac).
i
*note: See “PECO Compatible Accessories”
in Operating Manual to learn about additional
sensor applications.
▲
!
• warnInG: Disconnect power before beginning installation.
• caUtIon: Use copper wire only. Insulate or wire-nut all unused leads.
• Use care to avoid electrostatic discharge to thermostat
taBle 1. termInal DesIGnatIons anD sYstem tYPes
Figure 3.
Position
the wallplate
on the wall.
Pull wires
through
wiring passage.
wiring passage
terminal blocks enlarged