Chapter 5 - Setting up the NION
42
Version 1.6.1.0
September 30, 2010
Managing the role
In an NWare project, devices that are part of the design are assigned to roles, either
automatically by NWare or manually by the user. Each role is then assigned to a NION,
nControl unit or nTouch 180 unit for processing when the project is deployed.
Tip:
Once a project has been deployed to a node, if the node is power cycled, the project is
restarted automatically.
The
Audio
screen shows the NWare project to which the role belongs, the name of the role and
how long it has been loaded.
Restarting the role
1.
On the
Audio
screen, under
Role Actions
, click
Restart
.
2.
Click
OK
to confirm the action.
Stopping the role
1.
On the
Audio
screen, under
Role Actions
, click
Halt
.
2.
Click
OK
to confirm the action.
Erasing the role
1.
On the
Audio
screen, under
Role Actions
, click
Erase
.
2.
Click
OK
to confirm the action.
Specifying the function of the RS-232 serial port
The NION RS-232 serial port performs two main functions:
In
console
mode it allows a user to log on to the NION Linux Kernel via a serial terminal
session and change the configuration settings.
When console mode is disabled, you can control the NION using external protocols like
PASHA.
By default, console mode on the RS232 serial port is disabled.
To specify the function of the RS-232 serial port
1.
Open a browser window.
2.
Type the IP address of the NION in the
Address
bar, and then press Enter.
Содержание MediaMatrix Nion
Страница 1: ...NION Hardware Manual Version 1 6 1 0 September 30 2010...
Страница 8: ......
Страница 16: ......
Страница 20: ......
Страница 28: ...Chapter 4 Introduction to NION 24 Version 1 6 1 0 September 30 2010...
Страница 72: ......
Страница 86: ...Appendix C Technical specifications 82 Version 1 6 1 0 September 30 2010 AES card DIP switches...
Страница 92: ......