Appendix B - Connector ports
76
Version 1.6.1.0
September 30, 2010
So
me text to force a page break in Word but remain invisible
RS-422/485 serial port in RS-422 mode
Four RS-422 separate data pairs are provided for transmit (TX) and receive (RX).
Additionally, there is a 120 Ohm terminating resistor provided for each data pair for
applications that require an EOL termination. The termination is optional and is accessible by
connecting the terminating pin for each data transport pair.
To enable termination for the transmit pair, connect the terminating resistor pin (TX
Terminator) to the positive data transmit (TX+) pin.
To enable termination for the receive pair, connect the terminating resistor pin (RX
Terminator) to the positive data receive (RX+) pin.
Power (+12VDC) is provided on pin 4 and is referenced to ground, pin 5. The power pin is
protected by a self-resetting fuse and is limited to 0.5A, max.
Note:
Transmit (TX) and Receive (RX) are from the point of view of the NioNode. Connect
them to the opposite port of the remote unit.
Pin Function
Pin Function
1
TX Data +
6
TX 120 ohm terminating
resistor
2
TX Data -
7
RX Data +
3
RX 120 ohm terminating
resistor
8
RX Data -
4
+12 VDC (0.5A)
9
Reserved (no connection)
5 Ground
Содержание MediaMatrix Nion
Страница 1: ...NION Hardware Manual Version 1 6 1 0 September 30 2010...
Страница 8: ......
Страница 16: ......
Страница 20: ......
Страница 28: ...Chapter 4 Introduction to NION 24 Version 1 6 1 0 September 30 2010...
Страница 72: ......
Страница 86: ...Appendix C Technical specifications 82 Version 1 6 1 0 September 30 2010 AES card DIP switches...
Страница 92: ......