Loudspeaker System Specifications
9
GROUPING OF INSERT SETS
Group A
A set of two M10 inserts on the top, designed to hang the cabinet using the
proper eyebolts.
Group B
A set of two M10 inserts on the bottom, designed to hang the cabinet using the
proper eyebolts.
Group C
A set of four M8 inserts on the top, designed to be used with the Peavey
Versamount
™ 70 mounting bracket.
Group D
A set of four M8 inserts on the right side, designed to be used with the Peavey
Versamount
™ 70 mounting bracket.
Group E
A set of four M8 inserts on the bottom, designed to be used with the Peavey
Versamount
™ 70 mounting bracket.
For Group A and B, always use both inserts as a pair; NEVER use just one insert
to fly a cabinet!
For Group C, D and E, Always use all four inserts of a given group as a set;
NEVER use just one insert to fly a cabinet! The four insert groupings are meant
to have all four inserts used at once within a group.
Group E should only be used with the Versamount
™ 70 oriented beneath the
cabinet, and at an angle less than 30 degrees from vertical.
SPECIFICATIONS FOR INSERT MATING HARDWARE
Group A and Group B should use an M10 forged steel shoulder-type lifting
eyebolt, which meets the requirements of DIN 580 or ASTM A489. They should
only be used in pairs, and in conjunction with the rear most pair of M8 inserts on
the same surface as a pull-back/aiming adjustment, using M8 eyebolts of a
similar specification. The length of the threaded shank on the eyebolts should
not exceed 3 / 4” (approx. 20 mm), so that it does not bottom out in the insert.
Thread pitch: 1.5 mm per thread
Group C and D should use an M8, grade 8.8 or better, 1.25 mm per thread,
metric bolt, that does not penetrate the cabinet past the cabinet surface more
than 3 / 4 ” (approx. 20 mm). When using a Peavey Versamount™ 70 mounting