Offline on the supplied data carrier in the
Tools
directory branch
Unpack the downloaded
PEAK-Flash.zip
file to an arbitrary target directory on
your Windows computer or copy the
PEAK-Flash
directory from the data carrier.
The
PEAK-Flash.exe
file in the target directory is the executable to be used later.
4.1.3
Update Procedure
1. Apply power to the Evaluation Board.
2. Under Windows, start
PEAK-Flash.exer
.
Panel 1 of PEAK-Flash is shown with general information.
3. Click
Next
.
Panel 2
Select Hardware
of PEAK-Flash is shown.
4. Select
Modules connected to the CAN bus
.
5. From the list
Channels of connected CAN hardware
, select the CAN interface
that establishes the connection to the CAN bus.
6. From the
Bit rate
list, select 500 kbit/s (usually pre-selected).
7. Click
Detect
.
After a few seconds, a new entry with the name “PCAN-MicroMod FD Evalu-
ation Board” is shown in the field below, including the current module ID and
firmware version.
8. Click
Next
.
Panel 3
Select Firmware
of PEAK-Flash is shown.
9. Leave
Embedded Firmware
selected if it is suitable for the firmware update.
Alternatively:
Select
Firmware File
and then browse for the
*.bin
file to be flashed.
10. Click
Next
and check the provided information on panel 4 of PEAK-Flash.
4 Firmware Update of the PCAN-MicroMod FD
PCAN-MicroMod FD Evaluation Board
User Manual 1.1.0
© 2020 PEAK-System Technik GmbH
23