PCAN-Diag 2 – Technical Specifications
96
BNC connector
Functions
Trigger output or measuring input
Trigger output
Voltage idle state
+3.3 V
Voltage trigger event
0 V (falling edge)
Pulse duration
4 CAN bit timings, actual duration depending on the
set CAN bitrate
(at 500 kbit/s: 4 * 2
μ
s = 8
μ
s)
Delay to the internal trigger 140 CAN bit timings, actual duration depending on
the set CAN bitrate; is displayed in the scope
settings
Signal input
Use
Oscilloscope function, measuring channel 2 (Ch2),
for inspection of signals
Input voltage ranges
-3 - +15 V (low)
-10 - +50 V (high)
Maximum input voltage
±50 V
Maximum frequency input
signal
1 MHz
Probe usage
Standard probe without additional electronics
(not in the scope of supply)
Setting x1
Oscilloscope function
Measuring channels
1: CAN_H
2: CAN_L or BNC connector (max. 1 MHz)
Sampling frequency
max. 20 MS/s per measuring channel
Capacity sample buffer
max. 64,000 samples
Trigger types
CAN frame start/end, CAN ID, CAN error,
rising/falling edge measuring channel 2;
alternatively free-run mode
Pretrigger
10 %, 50 %, 90 %
Resolution time
measurement
50 ns (depending on zoom)
CAN-specific functions
Decoding of the recorded signal course
Data transfer
Screenshot of the current scope screen
Contents of the sample buffer as CSV file
Содержание IPEH-002069-V2
Страница 1: ...PCAN Diag 2 Handheld Device for CAN Bus Diagnostics User Manual V2 3 1 ...
Страница 6: ...PCAN Diag 2 User Manual 6 11 4 PCAN Diag Files on the Internal Memory Card 93 ...
Страница 43: ...PCAN Diag 2 CAN Traffic 43 Data display after assigning the symbol file in the PCAN Diag ...
Страница 98: ...PCAN Diag 2 Appendix 98 ...
Страница 99: ...PCAN Diag 2 Appendix 99 The figure does not show the original size dimensions for case without rubber sleeve ...