PCAN-Diag 2 – Setting Up the Device
15
Note:
If the device is equipped with a Low-speed or a Single-
wire CAN transceiver, GND must always be connected
(reference potential for the auxiliary supply), otherwise the CAN
communication does not work.
For separate ground connection to other CAN nodes or measuring
objects an additional 4-millimeter
GND socket
is provided on the
rear of the device.
GND socket (4 mm) on the rear of the device
The PCAN-Diag can be supplied in two ways:
externally via the supply socket (section 2.2.1)
temporarily by (rechargeable) batteries (section 2.2.2)
While operation, supply status is shown on the screen's upper
status bar.
Symbol Meaning
The device is connected to an external voltage source (e.g. AC adaptor)
The device is supplied by the inserted (rechargeable) batteries. An
estimation on the remaining capacity is given.
Note:
Inserted rechargeable batteries are not charged during
external supply.