PCAN-Diag 2 – Configuring the Device with Projects
77
7
Main menu item
Projects
With projects the PCAN-Diag can quickly be adapted to different
applications.
A project contains the following elements:
Project element
Assigned area in the PCAN-Diag
Device settings
Device Settings
Oscilloscope settings
Scope
>
Setting
Display settings for the D-Sub
measurement
Measurements
>
D-Sub Connector
>
Settings
CAN transmit lists
CAN Data
>
Manage Transmit Lists
Symbol files
CAN Data
>
Manage Symbol Files
Alternative splash screen
Intro.bmp
(see section 7.2 on page 84)
Shown when device is started
Using projects:
Projects are created and altered on a PC with the provided
Windows software PCAN-Diag Editor and then are transferred to
the internal memory card of the PCAN-Diag.
Any number of projects can be saved to the internal memory
card.
During work with the PCAN-Diag a project can be loaded from
the internal memory card.
If a new version of the active project is available on the internal
memory card, the project is automatically loaded during startup
of the PCAN-Diag.
Device-internal changes of the settings or of CAN transmit lists
do not alter the affiliated project on the internal memory card.
Содержание IPEH-002069-V2
Страница 1: ...PCAN Diag 2 Handheld Device for CAN Bus Diagnostics User Manual V2 3 1 ...
Страница 6: ...PCAN Diag 2 User Manual 6 11 4 PCAN Diag Files on the Internal Memory Card 93 ...
Страница 43: ...PCAN Diag 2 CAN Traffic 43 Data display after assigning the symbol file in the PCAN Diag ...
Страница 98: ...PCAN Diag 2 Appendix 98 ...
Страница 99: ...PCAN Diag 2 Appendix 99 The figure does not show the original size dimensions for case without rubber sleeve ...