PCAN-Diag 2 – Measuring Functions for the CAN Bus
56
Menu item
Measurements
>
CAN Termination
Note:
This function is only available if the PCAN-Diag is
equipped with a High-speed CAN transceiver (display at
Device Settings
:
Transceiver: High speed
).
The function measures the resistance value between the CAN_L and
CAN_H lines. While doing so the CAN traffic is not affected.
A High-speed CAN bus (ISO 11898-2) must be terminated with
120
Ω
on both ends between the CAN lines CAN_L and CAN_H. This
measure will prevent signal reflections at the cable ends and a
correct function of CAN transceivers attached to the CAN bus is
assured.
The two termination resistors in parallel result in a total resistance
of 60
Ω
. The measurement of the total resistance provides informa-
tion about a correct CAN bus termination.
Содержание IPEH-002069-V2
Страница 1: ...PCAN Diag 2 Handheld Device for CAN Bus Diagnostics User Manual V2 3 1 ...
Страница 6: ...PCAN Diag 2 User Manual 6 11 4 PCAN Diag Files on the Internal Memory Card 93 ...
Страница 43: ...PCAN Diag 2 CAN Traffic 43 Data display after assigning the symbol file in the PCAN Diag ...
Страница 98: ...PCAN Diag 2 Appendix 98 ...
Страница 99: ...PCAN Diag 2 Appendix 99 The figure does not show the original size dimensions for case without rubber sleeve ...