25
R. Install electrical system
Connect the power source on the data plate of Power Unit.
Note: 1. Install the limit switch
2. For the safety of operators, the earth wire must contact the floor well.
3. Pay attention to the direction of rotations when using three phase motors.
Single phase motor
(See Fig. 38).
1. Connecting the two power supply lines (active wire
L
and neutral wire
N
) to
terminals
L1, L2
of AC contactor respectively.
2. Connecting the two motor wires to
T1, T2
terminals of AC contactor
3. Connecting
terminal A2
to terminal
L2
of AC contactor.
4. Connecting the limit switch: Removing the wire of connecting terminal
4#
of
control button and
A1
of AC contactor firstly
(See Fig. 39)
, then connecting
wire
12#
(brown wire) of limit switch with terminal
4#
of control button and
connecting wire
11#
(blue wire) with terminals
A1
of AC contactor respectively.
Connecting the earth wire (yellow and green wire) of limit switch to the earth wire
terminal on the motor.
(See Fig. 40)
.
5. Connecting the terminal 3# on the control button to the terminal L1 on the AC
contactor.
Fig. 38
Содержание 211SAC
Страница 1: ...TWO POST LIFT Model 211SAC Original ...
Страница 10: ...8 D Install parts of extension columns See Fig 16 Fig 16 24 26 20 42 25 37 41 ...
Страница 18: ...16 K Raise the carriages up by hand and make them be locked at the same level See Fig 26 Fig 26 ...
Страница 20: ...18 1 2 Connecting cable for high setting See Fig 28 Cable 1 Cable 2 Cable 1 High setting Fig 28 ...
Страница 22: ...20 M Install power unit See Fig 30 Fig 30 ...
Страница 30: ...28 IV EXPLODED VIEW Model 211SAC Fig 43 ...
Страница 36: ...34 4 5 POWER UNIT EXPLODED VIEW 81513003 81513004 220V 50Hz Single Phase 380V 50Hz Three phase Fig 48 ...
Страница 45: ...43 ...
Страница 46: ...44 Date 2021 01 Manual No 72221707 ...