11
G. Position the columns
Position the columns on the installation layout of base plate. Install the anchor bolts.
Check the columns plumpness with level bar, and adjusting with the shims if the
columns are not vertical. Do not tighten the anchor bolts
(See Fig.20)
.
Note:
Minimum embedment of Anchors is
110mm
.
Drilling
Cleaning
Bolting
11
0m
m
Width between
columns:2850mm
Overall width
:
3542mm
Adjusting with
the shims
56
10
55
Fig.20
Содержание 211SAC