9.

 

To Attach a Filter

, line up the three tabs on the filter with the slots on the front 

of the searchlight.  Place  filter  over  front  of searchlight and turn  filter counter-
clockwise until fully seated.  Filter will lock in place.  For filter options, see the 
Filters and Accessories section of this manual. 

 

Searchlight Programming

 

 
The  Maxa  Beam  Searchlight’s  operational  characteristics  can  be  modified  using  a 
series  of  simple  programming  sequences.    This  capability  allows  the  light  to  be 
customized for specific applications.  For example, if  the searchlight will be utilized 
for  an  extended  search  operation,  the  searchlight  can  be  programmed  to  start  up  in 
low  beam  mode  with  the  beam  width  at  full  flood.    Other  scenarios  include  a 
surveillance  operation where the light must start up at normal  power with the beam 
set  to  the  size  of  the  area  under  surveillance  or  a  tactical  application  where  the 
searchlight is programmed to start up in strobe mode with a narrow beam spread. 
 

Factory Default Settings: 

 
MBS-410, MBS-430-W4, MBS-430-Y and MBPKG-E Series Searchlights 
 

Automatic Beam Intensity at Start-Up 

Normal Beam Level 

 

Rock 4-Way Switch Forward 

Decrease Beam Width to Spot 

 

Rock 4-Way Switch Back 

Increase Beam Width to Flood 

 

Rock 4-Way Switch Left 

Momentary Strobe Mode 

 

Rock 4-Way Switch Right 

Momentary High Beam 

 
MBS-430-W(-RS) Crew-Served Weapon Lights 
 

Automatic Beam Intensity at Start-Up 

High Beam Level 

 

Rock 4-Way Switch Forward 

Decrease Beam Width to Spot 

 

Rock 4-Way Switch Back 

Increase Beam Width to Flood 

 

Rock 4-Way Switch Left 

Latching Sweep Strobe Mode* 

 

Rock 4-Way Switch Right 

Toggles Latching High/Low Beam 

 

*The Sweep Strobe function is not user-programmable on MBS-430-W(-RS) lights. 

 
To modify these characteristics follow the instructions on the following pages. 

Содержание MAXA BEAM MBPKG-E

Страница 1: ...l e r R o a d E d g e m o n t P A1 9 0 2 8 P h o n e 6 1 0 3 5 3 8 5 0 5 F a x 6 1 0 3 5 3 8 4 1 1 w w w p e a k b e a m c o m s a l e s p e a k b e a m c o m H i g h I n t e n s i t y X e n o n S e a...

Страница 2: ...5 Rechargeable Battery Systems 8 MBP 1308 Lithium Iron Phosphate Batteries Searchlight Accessories 11 Searchlight Maintenance 12 Focusing the Lamp Lamp and Lens Replacement Technical Assistance 16 Re...

Страница 3: ...e rechargeable Lithium Iron Phosphate LiFePO4 batteries that offer up to 150 minutes of continuous operation from a single battery The searchlight and battery weigh just 6 5 lbs Remote Controlled Sear...

Страница 4: ...and infrared radiation emitted from this searchlight Permanent eye damage can result Avoid direct exposure to the beam Do not look directly into the searchlight beam Exposure of the eye to either the...

Страница 5: ...ght On press the red ON OFF SWITCH Searchlight starts on high power holds setting for 2 seconds then drops to normal power 6 To Adjust Beam Width pull the black 4 WAY SWITCH back to increase beam widt...

Страница 6: ...ormal power with the beam set to the size of the area under surveillance or a tactical application where the searchlight is programmed to start up in strobe mode with a narrow beam spread Factory Defa...

Страница 7: ...ates momentary strobe mode when the 4 way switch is held to the left To change the left switch function to continuous strobe mode follow the below sequence To change to low beam mode repeat the above...

Страница 8: ...e To follow this procedure the light must be in continuous strobe mode see B H To Lock Out Programming Functions This will prevent modifications from being made to programming settings after they are...

Страница 9: ...the Maxa Beam Searchlight offering a longer run time faster charge time and more life cycles than any previous Maxa Beam battery MBP 1308 Series Batteries are available with an optional fuel gauge For...

Страница 10: ...excepted batteries such as the MBP 1308 LiFePO4 Battery are not subject to certain provisions of the regulations e g Class 9 labeling and UN specification packaging Batteries shipped within the United...

Страница 11: ...LiFePO4 Chargers 1 Locate the MBP 3200 Smart Charger and compatible charging adapter see adapters on page 8 Connect adapter to appropriate input power source 2 Plug the female end of the charging ada...

Страница 12: ...B9 Serial Cable 25 Ft also available MBA GUI Maxa Beam Control Software Other Accessories MBA 6200 Small Watertight Storage Case with Die Cut Foam MBA 6250 Medium Watertight Storage Case with Die Cut...

Страница 13: ...ly seated into the internal adjustment screw hole 4 After the hex driver has been inserted into the adjustment screw turn the driver slightly to rotate the screw Notice how the hot spot of the beam mo...

Страница 14: ...ht front lens is removed or the lamp is being handled ALWAYS disconnect the searchlight from power when performing maintenance Never perform maintenance on a searchlight connected to power NEVER touch...

Страница 15: ...of the light Ensure that the front lamp support seats into the center locator of the lens Once the front lens O ring and lamp are positioned correctly secure the assembly in place with three new Lens...

Страница 16: ...Lens Lamp Support and Spring When in doubt reuse the existing Lamp Support and Spring that were previously installed in your searchlight as these should be compatible with your existing lens 6 Remove...

Страница 17: ...y to the power input connector When wiring the on off switch and remote control switches line 1 must be tied to one side of all switches in parallel The Ground pin is chassis ground and should be wire...

Страница 18: ...ut B Black Focus Narrow C Green Strobe Low Beam Mode D Orange On Off E Grey RS 232 Signal Ground DB9 Pin 5 F Blue Ground not connected on MBPKG E2 Series G Brown High Normal Beam H Yellow Focus Wide J...

Страница 19: ...put Searchlight Systems MBPKG E 24 MBPKG E2 24 Parameter Min Typ Max Unit Notes Operating Voltage 18 0 24 0 36 0 Volts Reverse Polarity Protected to 50V Lamp Off 0 20 0 23 Amps 25 C 24VDC Input Low Be...

Страница 20: ...in ReadMe Before Install document included on software CD Device Not Found error upon software launch Searchlight not connected OR COM Port not assigned Check Searchlight connection and power OR Cons...

Страница 21: ...the price of the goods upon which such liability is based In no event shall Peak Beam Systems Inc be liable for direct indirect or consequential damages loss of anticipated profits loss of time or an...

Страница 22: ...21 Proud to be made in the U S A Copyright 2018 Peak Beam Systems Inc...

Отзывы: