background image

2

639415 Rev0 – 4/22/21

6300M/MF EXIT INSTALLATION INSTRUCTION

MORTISE DEVICE

5. INSTALL DEVICE SPINDLE

 

Install spindle and spring in orientation 
shown on push side of door.

6. INSTALL DEVICE

 

Install device and trim with 1/4-20 screws 
from the hardware kit. 

 

Device can be surface mounted to the 
door, optional sex nuts are available, 
device is through bolted when using trim.

4. SIZE DEVICE

 

Standard lengths are for 36" or 48" door. 
Device must be cut for other lengths.

 

Mark length with tape – length equals 
device size minus desired door size (for 
30" door = cut 6" off 36" device) ensuring 
a square cut.

Panic Fire Alarm MLR

36" Device

6"

8"

2"

3"

48" Device 12"

14"

8"

9"

Maximum cut off length:

Reinforced Steel 
or Aluminum Door

Surface Mount: Drill/Tap push 
side for 1/4-20

Solid Wood Door Drill 1/8" Pilot Hole for #10 Wood 
All Others

Use optional Sex Bolts. Drill push 
side with 9/32" drill bit. Drill pull 
side with 3/8" drill bit.

Mounting Options: